Efficacy of ReBound Diathermy as a Thermal Heating Agent: A Critically Appraised Topic

Author:

Rhode Alissa C.,Lavelle Lauren M.,Berry David C.

Abstract

Clinical Scenario: ReBound is a portable shortwave diathermy unit used to heat tissues using the same principle as induction drum shortwave diathermy. It is unclear if ReBound can vigorously (4°C) heat intramuscular tissue as efficiently as other thermal agents. Clinical Question: In adults (P), is ReBound diathermy (I) compared with other thermal agents (C) effective at increasing intramuscular tissue temperature by 4°C (O)? Summary of Key Findings: (1) Three studies were included for review, all randomized crossover studies. (2) All studies agreed ReBound does not achieve vigorous (4°C) heating effects during a 30-minute treatment to the triceps surae muscle (depth = 1 and 3 cm). (3) Studies agreed that the heat generated by ReBound dissipates slower than (P < .001) or similar to pulsed shortwave diathermy at 3 cm and faster than moist hot packs (P < .001) at 1 cm. (4) One study found that intramuscular tissue temperatures increased more with ReBound (3.69°C [1.50°C]) than moist hot packs (2.82°C [0.90°C]) at superficial depths (1 cm, d = 0.70). (5) Two studies compared ReBound with MegaPulse II pulsed shortwave diathermy at a 3 cm depth. One found that the MegaPulse II increased intramuscular tissue temperature by 4.32°C (1.79°C) compared with the ReBound’s 2.31°C (0.87°C) increase (d = 1.43). The final study reported that the MegaPulse II increased triceps surae muscle temperature by 3.47°C (0.92°C) versus ReBound at 3.08°C (1.19°C) (d = 0.37). (6) The combined results are an increase of 3.81 (1.38°C) for the MegaPulse II and 2.77 (1.12°C) for ReBound (d = 0.83). Clinical Bottom Line: Results strongly indicate that the ReBound should not be used for vigorous (4°C) heating effects in the triceps surae muscle at 1 and 3 cm. Clinicians can use ReBound when traveling or instead of moist hot packs for moderate (2°C–3°C) heating effects at deep and superficial levels (1 and 3 cm) for large treatment areas with subcutaneous fat thickness <15 mm. Strength of Recommendation: Consistent level B findings indicate that ReBound does not achieve vigorous heating effects (4°C).

Publisher

Human Kinetics

Subject

Rehabilitation,Physical Therapy, Sports Therapy and Rehabilitation,Orthopedics and Sports Medicine,Biophysics

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3