Validity and Reliability of the Kinvent Handheld Dynamometer in the Athletic Shoulder Test

Author:

Olds Margie12ORCID,McLaine Sally3ORCID,Magni Nico4ORCID

Affiliation:

1. Flawless Motion Ltd, Auckland, New Zealand

2. Department of Physiotherapy, Otago University, New Zealand

3. Physiotas Launceston, School of Health Sciences, University of Tasmania, Hobart, TAS, Australia

4. Department of Physiotherapy, School of Clinical Sciences, Auckland University of Technology, Auckland, New Zealand

Abstract

Context: Long-lever shoulder strength tests may aid clinical decision-making regarding return to sport after a shoulder injury. The Athletic Shoulder Test (AST) was developed to measure force production in 3 positions of shoulder abduction (90°, 135°, and 180°) using force plates. However, handheld dynamometers (HHDs) are more portable, affordable, and may provide valid and reliable results which would increase the clinical utility of long-lever tests. HHDs vary in shape, design, and their capacity to report parameters such as rate of force production and require further investigation. The aim of this study was to examine the intrarater reliability of the Kinvent HHD and assess its validity against Kinvent force plates in the AST. Peak force (in kilograms), torque (in Newton meters), and normalized torque (in Newton meters per kilogram) were reported. Design: Validity and reliability study. Methods: Twenty-seven participants with no history of upper limb injury performed the test in a randomized order using the Kinvent HHD and force plates. Each condition was assessed 3 times, and peak force was recorded. Arm length was measured to calculate peak torque. Normalized peak torque was calculated by dividing torque by bodyweight (in kilograms). Results: The Kinvent HHD is reliable when measuring force (intraclass correlation coefficient [ICC] ≥ .80), torque (ICC ≥ .84), and normalized torque (ICC ≥ .64) during the AST. The Kinvent HHD is also valid when compared with the Kinvent force plates for force (ICC ≥ .79; r ≥ .82), torque (ICC ≥ .82; r ≥ .76), and normalized torque (ICC ≥ .71; r ≥ .61). There were no statistically significant differences across the 3 trials on analyses of variance (P > .05). Conclusions: The Kinvent HHD is a reliable tool when used to measure force, torque, and normalized torque in the AST. Furthermore, given the lack of significant difference between trials, clinicians can use one test to accurately report relative peak force/torque/normalized torque rather than average 3 separate trials. Finally, the Kinvent HHD is valid when compared with Kinvent force plates.

Publisher

Human Kinetics

Subject

Rehabilitation,Physical Therapy, Sports Therapy and Rehabilitation,Orthopedics and Sports Medicine,Biophysics

Reference20 articles.

1. Prevention of shoulder injuries in overhead athletes: a science-based approach;Cools AM,2015

2. Muscle mass, strength, and physical performance predicting activities of daily living: a meta‐analysis;Wang DX,2020

3. Shoulder internal and external rotation strength and prediction of subsequent injury in water‐polo players;Hams AH,2019

4. Normalizing physical performance tests for body size: aproposal for standardization;Jaric S,2005

5. Hand-held dynamometry correlation with the gold standard isokinetic dynamometry: a systematic review;Stark T,2011

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3