Criterion Validity and Reliability of Knee Frontal Plane Projection Angles Measured Using the Technique Application

Author:

Atkins Lee T.1,Van Bastian Tyler2,Eckert Sterling D.3,Hofmann Timothy R.4,Pierce Emily L.5,Richards Jim6,Selfe James7,Callaghan Michael7

Affiliation:

1. Department of Physical Therapy, University of North Texas Health Science Center, Fort Worth, TX, USA

2. New Mexico Orthopaedics, Rio Rancho, NM, USA

3. Fyzical Therapy and Balance Center, San Angelo, TX, USA

4. Advanced Clinical Associates, Scottsdale, AZ, USA

5. Athletico, Rockwall, TX, USA

6. Allied Health Research Unit, University of Central Lancashire, Preston, Lancashire, United Kingdom

7. Department of Health Professions, Manchester Metropolitan University, Manchester, United Kingdom

Abstract

Context: Abnormal knee frontal plane projection angles (FPPA) during movement have been associated with patellofemoral pain. As such, clinicians are interested in valid and reliable instruments suitable for broad-based clinical use that allow them to objectively measure such variables. Therefore, the purpose of the current study was to examine the criterion validity and reliability of knee FPPA measures obtained by clinicians using a free tablet application called Technique. Design: Validity/reliability study. Methods: To examine validity, the same raters measured 10, two-dimensional criterion reference angles at the first testing session. To examine reliability, the knee FPPA of 16 subjects was measured by 6 raters (3 physical therapists and 3 student physical therapists) on 2 separate occasions while performing a single-limb step-down task. Validity was investigated by calculating the 95% limits of agreement, mean absolute differences, and Bland–Altman plots. Reliability was examined by calculating intraclass correlation coefficients and the SE of measure. Results: For validity, the mean absolute difference between rater and criterion reference angle measures ranged from 0.20° to 0.90°. Ninety-five percent of expected errors between rater and criterion reference angle measures were 2.04° or less. For reliability, the intraclass correlation coefficient values for interrater and intrarater reliability were excellent ranging from .994 to .998 with SE of measure ranging from 0.44° to 0.84°. Conclusions: These findings indicate that knee FPPA measures obtained during a single-limb step-down task using the Technique tablet application are valid and reliable, and suitable for clinical use.

Publisher

Human Kinetics

Subject

Rehabilitation,Physical Therapy, Sports Therapy and Rehabilitation,Orthopedics and Sports Medicine,Biophysics

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3