Is Real-Time Poolside Assessment of Upper Limb Errors in Front Crawl Swimming Technique Reliable and Equivalent to Video Analysis?

Author:

Pollen Travis R.1ORCID,Ebaugh David2,Mohring Jason1,Hutchinson Dean3,Silfies Sheri P.4ORCID

Affiliation:

1. Department of Physical Therapy & Rehabilitation Sciences, Drexel University, Philadelphia, PA, USA

2. Department of Physical Therapy, University of Delaware, Newark, DE, USA

3. Strive Swim Science Center, Moorestown Field House, Moorestown, NJ, USA

4. Department of Exercise Science, Program in Physical Therapy, University of South Carolina, Columbia, SC, USA

Abstract

Context: Swimming technique is widely believed to influence performance, but this relationship has rarely been tested objectively using a real-time poolside assessment. Objective: To determine the (1) test–retest reliability, interrater reliability, and criterion validity (live vs video) of real-time poolside assessment of upper limb (UL) errors in front crawl (FC) swimming technique and (2) the relationship between UL errors and FC swimming performance. Design: Cross-sectional reliability, validity, and correlational study. Setting: Swim team practice at a college natatorium. Participants: Thirty-nine Division III college swimmers (21 women and 18 men, age = 19 [1] y, swimming experience = 11 [3] y). Main Outcome Measures: Seven UL errors in FC swimming technique, many of which involved unnecessary vertical and mediolateral motions, were assessed in real time from outside the pool during swim practice. Test–retest reliability, interrater reliability, and criterion validity were calculated using Cohen kappa (κ) and weighted kappa (κw). Swimming performance was determined by the participants’ best FC events relative to the conference records. The correlation between total UL errors and FC swimming performance was assessed with Pearson r. Results: Cohen κ and κw were moderate for the majority of errors, with the following ranges: 0.46 to 0.90 (test–retest), −0.01 to 1.00 (interrater), and 0.36 to 0.66 (criterion validity). There was a significant correlation between total UL errors and FC swimming performance: r(24) = −.59 (P = .001, R2 = .35). Conclusions: Reliability and validity were moderate for the majority of errors. The fewer UL errors swimmers made while practicing FC, the faster their best FC race times tended to be relative to the conference record. UL errors in FC swimming technique explained 35% of the variance in performance.

Publisher

Human Kinetics

Subject

Rehabilitation,Physical Therapy, Sports Therapy and Rehabilitation,Orthopedics and Sports Medicine,Biophysics

Cited by 3 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3