Abstract
Introduction: Instrumented gait mat systems have been regarded as one of the gold standard methods for measuring spatiotemporal gait parameters. However, their portable walkways confine walking to a restricted area and limit the number of gait cycles collected. Wearable inertial sensors are a potential alternative that allow more natural walking behavior and have fewer space restrictions. The objective of this pilot study was to establish the concurrent validity of body-worn sensors against the portable walkway system in older children. Methods: Twenty-one participants (10 males) 7–17 years old performed 2-min walk tests at a self-selected and fast pace in a 25-m-long hallway, while wearing three inertial sensors. Data collection were synchronized between devices and the portions of the walk when subjects passed on the walkway were used to compare gait speed, stride length, gait cycle duration, cadence, and double support time. Regression models and Bland–Altman analysis were completed to determine agreement between systems for the selected gait parameters. Results: Gait speed, cadence, gait cycle duration, and stride length as measured by inertial sensors demonstrated strong agreement overall. Double support time was found to have lower validity due to a combined bias of age, height, weight, and walking pace. Conclusion: These results support the validity of wearable inertial sensors in measuring gait speed, cadence, gait cycle duration, and stride length in children 7 years old and above during a 2-min walking test. Future studies are warranted with a broader age range to thoroughly represent the pediatric population.
Reference76 articles.
1. Physical function and muscle strength in sporadic inclusion body myositis;Jørgensen;Muscle & Nerve,,2017
2. Spatio-temporal parameters of gait measured by an ambulatory system using miniature gyroscopes;Aminian;Journal of Biomechanics,,2002
3. Comparison of hallway and treadmill six-minute walk tests;Stevens;American Journal of Respiratory and Critical Care Medicine,,1999
4. Comparison of hallway and treadmill six-minute walk tests;Stevens;American Journal of Respiratory and Critical Care Medicine,,1999
5. Mobile gait analysis via eSHOEs instrumented shoe insoles: A pilot study for validation against the gold standard GAITRite®;Jagos;Journal of Medical Engineering & Technology,,2017