A Self-Paced Walk Test for Individual Calibration of Heart Rate to Energy Expenditure

Author:

Westgate Kate1ORCID,Gonzales Tomas I.1ORCID,Hollidge Stefanie1,Lindsay Tim1ORCID,Wareham Nick1ORCID,Brage Søren1ORCID

Affiliation:

1. MRC Epidemiology Unit, University of Cambridge, Cambridge, United Kingdom

Abstract

Introduction: Estimating free-living physical activity (PA) with continuous heart rate (HR) monitoring is challenging due to individual variation in the relationship between HR and energy expenditure. This variation can be captured through individual calibration with graded exercise tests, but structured tests with prescribed load require medical screening and are not always feasible in population settings. We present and evaluate an individual calibration method using HR response to a less demanding self-paced walk test. Methods: Six hundred and forty-three participants from the Fenland Study (Cambridgeshire, the United Kingdom) completed a 200-m self-paced walk test, a treadmill test, and 1 week of continuous HR and accelerometry monitoring. Mixed-effects regression was used to derive a walk test calibration model from HR response to the walk using treadmill-based parameters as criterion. Free-living PA estimates from the calibration model were compared with treadmill-calibrated and non-exercise-calibrated estimates. Results: Walk calibration captured 57% of the variance in the HR–energy expenditure relationship determined by the treadmill test. Applying walk calibration to data from free-living yielded similar PA estimates to those using treadmill calibration (52.7 vs. 52.0 kJ·kg−1·day−1; mean difference: 0.7 kJ·kg−1·day−1, 95% confidence interval [−0.0, 1.5]) and high correlation (r = .89). Individual differences were observed (root mean square error: 10.0 kJ·kg−1·day−1; 95% limits of agreement: −20.6, 19.1 kJ·kg−1·day−1). Walk calibration improved precision by 29% compared with nonexercise group calibration (root mean square error: 14.0 kJ·kg−1·day−1; 95% limits of agreement: −30.4, 24.5 kJ·kg−1·day−1). Conclusions: A 200-m self-paced walk test captures between-individual variation in the HR–energy expenditure relationship and facilitates estimation of free-living PA in population settings.

Publisher

Human Kinetics

Reference32 articles.

1. Net heart rate as a substitute for respiratory calorimetry;Andrews, R.B.,1971

2. Measures of physical performance assessments: Self-Paced Walk Test (SPWT), Stair Climb Test (SCT), Six-Minute Walk Test (6MWT), Chair Stand Test (CST), Timed Up & Go (TUG), Sock Test, Lift and Carry Test (LCT), and Car Task;Bennell, K.,2011

3. Branched equation modeling of simultaneous accelerometry and heart rate monitoring improves estimate of directly measured physical activity energy expenditure;Brage, S,2004

4. Hierarchy of individual calibration levels for heart rate and accelerometry to measure physical activity;Brage, S,2007

5. Brage, S., et al. (2013). Evaluation of a method for minimising diurnal information bias in objective sensor data. 3rd International Conference on Ambulatory Monitoring of Physical Activity and Movement, Amherst, MA, USA.

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3