Aerobic Capacity Determines Habitual Walking Acceleration, Not Electromyography-Indicated Relative Effort

Author:

Pesola Arto J.1,Rantalainen Timo2,Gao Ying3,Finni Taija4

Affiliation:

1. 1Active Life Lab, South-Eastern Finland University of Applied Sciences, Mikkeli, Finland

2. 2Gerontology Research Center, Faculty of Sport and Health Sciences, University of Jyväskylä, Jyväskylä, Finland

3. 3Department of Sports Science, College of Education, Zhejiang University, Hangzhou, China

4. 4Neuromuscular Research Center, Faculty of Sport and Health Sciences, University of Jyväskylä, Jyväskylä, Finland

Abstract

Objective: Habitual walking is important for health and can be measured with accelerometry, but accelerometry does not measure physiological effort relative to capacity. We compared accelerometer-measured absolute intensity and electromyography (EMG)-measured relative muscle activity between people with low versus excellent aerobic fitness levels during their habitual walking. Methods: Forty volunteers (19 women; age 49.3 ± 17.1 years, body mass index 24.0 ± 2.6 kg/m2; peak oxygen uptake 40.3 ± 12.5 ml/kg/min) wore EMG-shorts and a hip-worn accelerometer simultaneously for 11.6 ± 2.2 hr on 1.7 ± 1.1 days. Continuous gait bouts of at least 5-min duration were identified based on acceleration mean amplitude deviation (MAD, in milli gravitational acceleration, mg) and mean EMG amplitude, with EMG normalized to maximal isometric knee extension and flexion (EMG, in percentage of maximal voluntary contraction EMG). Peak oxygen uptake was measured on a treadmill and maximal strength in isometric leg press (leg press max). MAD and EMG were compared between age- and sex-specific fitness groups (low-average, good, and excellent) and in linear models. Results: During habitual walking bouts (4.1 ± 4.1 bouts/day, 0.9 ± 1.0 min/bout), the low-average fit participants had an approximately 28% lower MAD (245 ± 64.3 mg) compared with both good fit and excellent fit participants (313 ± 68.1 mg, p < .05), but EMG was the same (13.1% ± 8.42% maximal voluntary contraction EMG, p = .10). Absolute, relative to body mass, and relative to skeletal muscle mass peak oxygen uptake (but not leg press max) was positively associated with MAD independent of age and sex (p < .01), but there were no associations with EMG. Conclusions: People with low-average aerobic capacity habitually walk with a lower accelerometer-measured absolute intensity, but the physiological stimulus for lower-extremity muscles is similar to those with excellent aerobic capacity. This should be considered when measuring and prescribing walking for health.

Publisher

Human Kinetics

Subject

General Medicine

Reference88 articles.

1. Walking at the preferred stride frequency minimizes muscle activity;Russell;Gait & Posture,,2016

2. EMG, heart rate, and accelerometer as estimators of energy expenditure in locomotion;Tikkanen;Medicine and Science in Sports and Exercise,,2014

3. Calibration of accelerometer output for adults;Matthews;Medicine and Science in Sports and Exercise,,2005

4. Integrated electromyogram and oxygen uptake during positive and negative work;Bigland-Ritchie;The Journal of Physiology,,1976

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3