Effects of Transducer Mass on Intramuscular Temperature During Ultrasound Treatments

Author:

Krasinski Daniel,Thrasher Ashley B.,Miller Michael G.,Holcomb William R.

Abstract

Context:A potential variable that could affect rate of temperature elevation with ultrasound is the pressure (mass) that is applied to the transducer head during application. Added pressure could compress the tissue, affecting density and the transmission of ultrasound energy. Little research has been completed to determine the effects of the amount of pressure applied during therapeutic ultrasound in vivo.Objective:To determine the effects of different applied transducer mass on intramuscular temperature during an ultrasound treatment within the left triceps surae.Design:Crossover clinical trial.Setting:Human performance research laboratory.Participants:Convenience sample of thirteen healthy, college-age students.Interventions:Three separate MHz, 1.0-W/cm2 ultrasound treatments were administered 1.5 cm within the triceps surae. The independent variables were the linear temperature standards (0.5°C, 1.0°C, 1.5°C, and 2.0°C above baseline) and the 3 different applied pressures measured in grams (200 g, 600 g, and 800 g).Main Outcome Measures:A thermocouple probe was used to measure triceps surae temperature, and time to reach the temperature standards was recorded during the ultrasound treatments. A 4 × 3 repeated-measures analysis of variance (RM-ANOVA) was used to analyze the differences for temperature points (0.5°C, 1.0°C, 1.5°C, and 2.0°C) and transducer mass (200 g, 600 g, and 800 g) and with respect to time.Results:The results of the RM-ANOVA showed no temperature-point and transducer-mass interaction (F6,72 = 1.69, P = .137) or main effect for mass (F2,24 = 1.23, P = .309). The time required to raise temperature 2°C was 209.1 ± 68.10 s at 200 g, 181.5 ± 61.50 s at 600 g, and 194.9 ± 75.54 s at 800 g.Conclusions:Under the conditions of this study, the amount of mass applied with the transducer during an ultrasound treatment does not ultimately affect the rate of tissue heating.

Publisher

Human Kinetics

Subject

Rehabilitation,Physical Therapy, Sports Therapy and Rehabilitation,Orthopedics and Sports Medicine,Biophysics

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

1. Ultraschalltherapie;Evidenzbasierte Elektrotherapie;2022

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3