Reliability and Sensitivity of Nocturnal Heart Rate and Heart-Rate Variability in Monitoring Individual Responses to Training Load

Author:

Nuuttila Olli-Pekka1,Seipäjärvi Santtu2,Kyröläinen Heikki1,Nummela Ari3

Affiliation:

1. Faculty of Sport and Health Sciences, University of Jyväskylä, Jyväskylä, Finland

2. Department of Psychology, Center for Interdisciplinary Brain Research, University of Jyväskylä, Jyväskylä, Finland

3. Finnish Institute of High Performance Sport KIHU, Jyväskylä, Finland

Abstract

Purpose: To assess the reliability of nocturnal heart rate (HR) and HR variability (HRV) and to analyze the sensitivity of these markers to maximal endurance exercise. Methods: Recreational runners recorded nocturnal HR and HRV on nights after 2 identical low-intensity training sessions (n = 15) and on nights before and after a 3000-m running test (n = 23). Average HR, the natural logarithm of the root mean square of successive differences (LnRMSSD), and the natural logarithm of the high-frequency power (LnHF) were analyzed from a full night (FULL), a 4-hour (4H) segment starting 30 minutes after going to sleep, and morning value (MOR) based on the endpoint of the linear fit through all 5-minute averages during the night. Differences between the nights were analyzed with a general linear model, and intraclass correlation coefficient (ICC) was used for internight reliability assessments. Results: All indices were similar between the nights followed by low-intensity training sessions. A very high ICC (P < .001) was observed in all analysis segments with a range of .97 to .98 for HR, .92 to .97 for LnRMSSD, and .91 to .96 for LnHF. HR increased (P < .001), whereas LnRMSSD (P < .01) and LnHF (P < .05) decreased after the 3000-m test compared with previous night only in 4H and FULL. Increments in HR (P < .01) and decrements in LnRMSSD (P < .05) were greater in 4H compared with FULL and MOR. Conclusions: Nocturnal HR and HRV indices are highly reliable. Demanding maximal exercise increases HR and decreases HRV most systematically in 4H and FULL segments.

Publisher

Human Kinetics

Subject

Orthopedics and Sports Medicine,Physical Therapy, Sports Therapy and Rehabilitation

Cited by 11 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3