Author:
Lillo-Bevia José R.,Pallarés Jesús G.
Abstract
Purpose: To validate the new drive indoor trainer Hammer designed by Cycleops®. Methods: A total of 11 cyclists performed 44 randomized and counterbalanced graded exercise tests (100–500 W) at 70-, 85-, and 100-rpm cadences in seated and standing positions on 3 different Hammer units, while a scientific SRM system continuously recorded cadence and power output data. Results: No significant differences were detected between the 3 Hammer devices and the SRM for any workload, cadence, or pedaling condition (P value between 1.00 and .350), except for some minor differences (P = .03 and .04) found in the Hammer 1 at low workloads and for Hammer 2 and 3 at high workloads, all in seated position. Strong intraclass correlation coefficients were found between the power output values recorded by the Hammers and the SRM (≥.996; P = .001), independently from the cadence condition and seated position. Bland–Altman analysis revealed low bias (−5.5 to 3.8) and low SD of bias (2.5–5.3) for all testing conditions, except marginal values found for the Hammer 1 at high cadences and seated position (9.6 [6.6]). High absolute reliability values were detected for the 3 Hammers (150–500 W; coefficient of variation <1.2%; SEM <2.1). Conclusions: This new Cycleops trainer is a valid and reliable device to drive and measure power output in cyclists, providing an alternative to larger and more expensive laboratory ergometers and allowing cyclists to use their own bicycles.
Subject
Orthopedics and Sports Medicine,Physical Therapy, Sports Therapy and Rehabilitation
Cited by
29 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献