STRUCTURAL AND DURABILITY ANALYSIS OF A NOVEL RE-ROOFING CONCEPT
Author:
RICHMAN Russell1,
BENTZ Evan2,
JERMYN Denver1,
SUN Chang2
Affiliation:
1. Ryerson University
2. University of Toronto
Abstract
Metal roof decks in long-span light steel structures can become damaged and obsolete by corrosion should the roofing system become compromised. Re-roofing is conducted by either removing and replacing damaged areas (resulting in suspension of interior operations and lost revenue) or installing new decking directly over the damaged areas which can transfer corrosion to the new deck. This research conducts structural and durability analyses on a novel proposed re-roofing concept that installs a new metal roof deck over the existing deck by using a proprietary deck strap resulting in no interruption of interior processes. Preliminary structural analysis shows the proposed concept to be applicable to generic conditions around Southern Ontario. Recommendations for project specific structural analysis are made. Durability analysis demonstrates that the proposed concept system improves hygrothermal performance of the roof assembly in all cases except when insulation in the existing roof assembly is saturated. Saturated insulation should be removed prior to installing the re-roofing system.
Funder
Natural Sciences and Engineering Research Council of Canada
Publisher
Vilnius Gediminas Technical University
Cited by
1 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献
1. Reconstruction project of the main structure of the mortuary complex in Volzhsky RF;PROCEEDINGS OF THE 1ST INTERNATIONAL CONFERENCE ON FRONTIER OF DIGITAL TECHNOLOGY TOWARDS A SUSTAINABLE SOCIETY;2023