Affiliation:
1. Visvesvaraya National Institute of Technology
Abstract
This paper presents pin-ended compression tests on steel equal angles. Three nominal section sizes were tested. Detailed measurements of material properties, residual stresses, and geometrical imperfections were conducted. The pin ended specimens were tested with a minimal eccentricity of L/1,000 applied about the minor axis to cause compression at the tips of the legs. The test data are compared with the Indian specifications for hot-rolled steel structures. The section capacities obtained from the column tests are found to be between 15 and 40% higher than those calculated according to the specifications. It is concluded that there is no need to include the additional eccentricity specified in the steel structures standards accounting for the shift of the effective centroid, and that the eccentricity of L/1,000, specified for all section classes, should be applied to slender sections only.
Publisher
Vilnius Gediminas Technical University
Reference19 articles.
1. Analysis of equal leg single-angle section beams subjected to biaxial bending and constant axial compressive force
2. Bjorhovde, R. 1972. Deterministic and probabilistic approaches to the strength of steel columns: PhD dissertation. Lehigh University, Fritz Laboratory Reports.
Cited by
1 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献
1. Buckling Behavior of Schifflerized Angle Sections;Journal of The Institution of Engineers (India): Series A;2020-03-03