Affiliation:
1. University of _essaly
2. National Technical University of Athens
Abstract
During the operation of urban subway rail transit systems, vibrations are generated that transmitted through the soil, induce vibrations in nearby buildings. The transmission of ground-borne vibrations from subway rail transit systems in a building is governed by the soil-foundation interaction, the reduction of vibration level between floors, and the amplication due to resonances of building elements. These are influenced by the type of the building, its construction materials, the foundation soil, and the frequency content of the excitation. A methodology is proposed for the determination of the sound vibration along the height of the building for a specic construction type, demonstrating how the attenuation and amplication parameters can be calculated. For this particular building type, a notable amplication of the vibration due to floor and other structural resonances was found, whereas the vibration and hence the radiated noise levels are similar from the first floor up. An overall building amplication factor is proposed, taking into account all the above mentioned transmission mechanisms.
Publisher
Vilnius Gediminas Technical University
Subject
Mechanical Engineering,Automotive Engineering
Cited by
40 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献