Affiliation:
1. Hong Kong, China
2. No benefits in any form have been received or will be received from a commercial party related directly or indirectly to the subject of this article.
Abstract
Background: The purpose of this study was to verify the safety and efficacy of zone 2 flexor hallucis longus tendoscopy with the patient in the prone position. Materials and Methods: The technique was performed in 12 cadaver feet (6 pairs). The endoscopic findings were compared to an anatomic dissection. The locations of the posteromedial and plantar portals were studied. The relationship between the medial plantar nerve and the tract of FHL tendoscopy was also studied. Result: The average distance of the posteromedial portal above the medial malleolar tip was 10.3 mm. The average distance between the posteromedial portal and the posterior tibial nerve was 9.9 mm. The average distance between the plantar portal and the intermalleolar line was 41.5 mm. The average distance between the rod simulating the tenoscope and the nerve was 4.8 mm. The nerve was medial to the rod in 4 specimens and lateral to the rod in 8 specimens. Conclusion: Zone 2 flexor hallucis longus tendoscopy was a feasible approach to the deep portion of the flexor hallucis longus tendon in this cadaveric study. There is potential risk of damage to the medial plantar nerve. Clinical Relevance: These findings can help guide a surgeon who is considering trying this clinically.
Subject
Orthopedics and Sports Medicine,Surgery
Cited by
28 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献