Comparison of Augmentation Methods for Internal Fixation of Osteoporotic Ankle Fractures

Author:

Panchbhavi Vinod K.1,Vallurupalli Santaram1,Morris Randal1

Affiliation:

1. Galveston, TX

Abstract

Background: Internal fixation of osteoporotic ankle fractures is associated with failure of fixation. This study compared different augmentation methods biomechanically. Materials and Methods: In nine paired fresh-frozen cadaver legs, an identical supination-external rotation type II ankle fracture was created. Fractures were stabilized using an eight-hole locking plate. In four pairs, two screws were inserted across the syndesmosis for purchase in the tibial metaphysis. One leg from each pair was randomly selected for injection of calcium sulphate-calcium phosphate graft into the screw holes. Each leg was mounted to an MTS machine in a custom loading frame. Axial cyclic loading to body weight was performed to measure displacement at the fracture site, followed by rotational loading to failure simulating a supination external rotation injury. Data were analyzed using a two-way paired t -test and ANOVA. Results: The specimens used had a mean bone mineral density of 0.49 ± 0.15 (SD) g/cm2, and a mean age of 83 ± 12 years. In the biomechanical tests, there were no significant differences between augmented and non-augmented locking plates without the tibia-pro-fibula screws in axial stiffness ( p = 0.10), external rotation angle at failure ( p = 0.42), failure torque ( p = 0.57), energy absorbed before failure ( p = 0.47), and motion at the fracture site with cyclic axial loading ( p = 0.15). There were no significant differences between augmented and non-augmented locking plates with the tibia-pro-fibula screws in the external rotation angle at failure ( p = 0.83), failure torque ( p = 0.58), and failure energy ( p = 0.4). However, the overall strength of the fixation tended to increase with tibia-pro-fibula screws and augmentation. Conclusion: Internal fixation of an osteoporotic lateral malleolar fracture using a locking plate and screws provided a construct comparable in strength to that augmented with calcium sulfate-calcium phosphate graft and/or tibia-pro-fibula screws. Clinical Relevance: Strategies to augment internal fixation of osteoporotic ankle fractures may minimize risk for failure of fixation and may enable early weight bearing mobilization and return to function in elderly patients.

Publisher

SAGE Publications

Subject

Orthopedics and Sports Medicine,Surgery

Cited by 41 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3