Ultrasound Guidance for Intra-articular Injections of the Foot and Ankle

Author:

Khosla Shaun1,Thiele Ralf1,Baumhauer Judith F.1

Affiliation:

1. Rochester, NY

Abstract

Background: Ultrasound has been increasingly utilized in procedures involving intra-articular injections. This study's purpose was to compare the accuracy of intra-articular injections of the foot and ankle using palpation versus dynamic ultrasound in a cadaver model. Materials and Methods: Fourteen lightly embalmed cadaver specimens without notable osteoarthritis were used. A 0.22-gauge needle was placed by a foot and ankle orthopaedic surgeon into the first and second tarsometatarsal joints, subtalar joint, and ankle joint. The needle was initially placed using palpation, evaluated with ultrasound by an experienced rheumatologist, and re-inserted if necessary. Needle placement was confirmed with injection of an Omnipaque™/methylene blue solution and examined under fluoroscopy, followed by dissection. Results: Palpation and ultrasound were 100% accurate in subtalar and ankle joint injections. Using palpation, the needle was correctly placed into the first TMT joint in three of 14 cadavers, and in four of 14 cadavers for the second TMT joint. Using ultrasound, the needle was correctly placed into the first TMT joint in ten of 14 cadavers, and into the second TMT joint in eight of 14 cadavers. When grouped, ultrasound was significantly more accurate for intra-articular needle placement compared to palpation in the midfoot ( p = 0.003). On three specimens, dye extended beyond the second TMT joint. Conclusion: Intra-articular injections of the subtalar and ankle joints can be successfully performed utilizing palpation alone. Ultrasound guidance significantly increases injection accuracy into the TMT joints compared to palpation alone and therefore US or Fluoroscopy is performed when injecting these TMT joints. When using selective diagnostic injections into a TMT joint to assess for the symptomatic joint and potential need for arthrodesis, the injected anesthetic may not remain isolated within that joint. These isolated TMT injections should not be done to answer that question without fluoroscopy confirmation with radiopaue dye demonstrating the injected fluid remained within the one joint of interest.

Publisher

SAGE Publications

Subject

Orthopedics and Sports Medicine,Surgery

Cited by 67 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3