High Rate of Osteolytic Lesions in Medium-Term Followup after the AES Total Ankle Replacement

Author:

Kokkonen Ari1,Ikavalko Mikko1,Tiihonen Raine12,Kautiainen Hannu134,Belt Eero A.13

Affiliation:

1. Department of Orthopaedics, Rheumatism Foundation Hospital, FIN-18120 Heinola, Finland

2. Department of Orthopaedics, Päijät-Häme Central Hospital, Lahti, Finland

3. ORTON Orthopaedic Hospital, ORTON Foundation, Helsinki, Finland

4. Unit of Family Practice, Central Finland Central Hospital, Jyväskylä, Finland

Abstract

Background: Some previous studies have shown a high percentage of early-onset and rapidly progressing osteolysis associated with total ankle arthroplasty (TAA) by the Ankle Evolutive System (AES). The purpose of our study was to analyze medium-term results at our institution. Materials and Methods: Altogether 38 TAAs using AES prostheses were carried out between 2003 and 2007. Diagnoses were rheumatoid arthritis (71%), post-traumatic and idiopathic osteoarthritis (29%). The mean age was 54 years, followup 28 months. Tibial and talar components had hydroxyapatite coating on metal (Co-Cr) components (HA-coated). Since 2005 the design was changed and components were porous coated with titanium and hydroxyapatite (dual-coated). Results: Two-year survival was 79% (95% CI: 56 to 98). At followup 34 (89%) primary tibial and talar components were preserved. In 19 (50%) TAAs osteolysis (more than or equal to 2 mm) occurred in the periprosthetic bone area and in nine (24%) comprised large “cyst-like osteolysis”. In HA-coated prostheses radiolucent lines (less than or equal to 2 mm) or osteolysis (more than or equal to 2 mm) were detected in 11 (100%) cases and in dual-coated prostheses in 19 (74%) ( p= 0. 08). On the other hand there was more large “cyst-like osteolysis” around the dual-coated prosthesis and lesions were larger ( p= 0. 017). In rheumatoid arthritis osteolysis was detected in 14 (52%) and large “cyst-like osteolysis” in seven (26%) prostheses and in the group of traumatic and idiopathic osteoarthritis in six (55%) and two (18%), respectively. Conclusion: This study showed a high frequency of osteolysis in medium-term followup after the AES ankle replacement. The outcome was not sufficiently beneficial and we have discontinued use of this prosthesis. Level of Evidence: IV, Retrospective Case Series

Publisher

SAGE Publications

Subject

Orthopedics and Sports Medicine,Surgery

Cited by 69 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3