Abstract
Background: Structural bone grafts are often used in foot and ankle surgery to fill gaps, maintain height, length or correction. Bone graft, whether autograft or allograft, has limitations and disadvantages. With porosity and mechanical properties similar to native bone, porous tantalum has been used successfully in hip and knee applications. This study investigates the potential advantages of porous tantalum as a substitute for conventional bone graft in foot and ankle surgery. Methods: A retrospective review of 27 arthrodesis procedures was performed of foot and ankle procedures using Trabecular Metal™ porous tantalum over a period of 5 years. Twenty-five patients were involved. Mean age at the time of surgery was 63 (range, 41 to 80) years. All the patients had pathologies in the foot and ankle that required arthrodesis with structural graft. Average followup was 27 (range, 12 to 72) months. Results: At final followup the mean American Orthopaedic Foot and Ankle Society (AOFAS) Ankle-Hindfoot / Midfoot score improved from 40.6 (range, 16 to 64) preoperatively to 86.3 (range, 57 to 100) postoperatively ( p < 0.001). When the pain component of the AOFAS was examined, the score improved from a mean of 8.2 (range, 0 to 20) to 35.2 (range, 20 to 40), ( p < 0.001). At the time of last followup, 56% of patients reported no pain, 40% reported mild occasional pain, and 4% reported moderate pain. Conclusion: Porous tantalum therefore, was found to be a viable alternative to conventional bone graft when structural support was required.Level of Evidence: IV; Retrospective Case Series
Subject
Orthopedics and Sports Medicine,Surgery
Cited by
38 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献