Three-Dimensional Fluoroscopy For Evaluation of Articular Reduction and Screw Placement in Calcaneal Fractures

Author:

Kendoff Daniel1,Citak Musa1,Gardner Michael2,Kfuri Maurico3,Thumes Barbara1,Krettek Christian1,Hüfner Tobias1

Affiliation:

1. Trauma Department, Hannover Medical School, Hannover, Germany

2. Orthopaedic Department, Hospital for Special Surgery, New York, NY

3. Universidade de São Paulo, Ribeirao Preto, Brazil

Abstract

Background: Anatomic reconstruction of the posterior calcaneal facet after intra-articular fracture is one of the critical factors in achieving a good functional result. Intraoperative evaluation of fracture reduction and implant placement relies on direct view by standard fluoroscopy. We hypothesized that three-dimensional (3D) fluoroscopy is more accurate than conventional fluoroscopy, and equivalent to CT for determining fracture reduction and screw position in calcaneal fractures. Methods: A Sanders type IIB fracture pattern was created in eight embalmed lower extremity cadaver specimens. First, the posterior facet was reduced with a step-off of 0 mm to 2 mm in 0.5-mm increments. All specimens had two dimensional (2D) fluoroscopy, 3D fluoroscopy with an Iso-C3D, and a CT scan. Next, screws were placed so they protruded into the subtalar and calcaneocuboid joint and through the medial wall. All specimens were imaged again. Three observers evaluated all imaging studies, and the sensitivities and specificities of each modality were determined. Results: Both the Iso-C3D and the CT were more specific for anatomic reduction (75% and 100%, respectively) than fluoroscopy (62%). For the malreduced trials, the Iso-C3D and CT were both 100% sensitive, and the sensitivity of fluoroscopy was 63% ( p < 0.001 for both). For the intra-articular screws, the Iso-C3D and CT were accurate in all cases (sensitivities = 100%), and fluoroscopy was accurate in five of the eight trials for both joints (sensitivities = 63%). Finally, with screws protruding through the medial wall, the sensitivity of fluoroscopy was 25%, for the Iso-C3D 88% ( p = 0.02), and for CT was 100% ( p = 0.003). Conclusions: Three-dimensional fluoroscopic imaging is more accurate than 2D fluoroscopy for detection of intra-articular incongruities and implant position and is similar to CT. Clinical Relevance: This new technology may be particularly useful in assessing calcaneal fractures and may lead to improved fracture reduction, less implant misplacement, and improved patient outcomes.

Publisher

SAGE Publications

Subject

Orthopedics and Sports Medicine,Surgery

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3