The position of ground electrode affects electrocardiographic parameters in horses

Author:

Kenchaiwong Wootichai1ORCID,Sangpo Pamika2,Kusol Anawach2,Pontaema Theerapong3ORCID,Lerdweeraphon Wichaporn4ORCID

Affiliation:

1. Applied Animal Physiology Research Unit, Faculty of Veterinary Science, Mahasarakham University, Thailand; Small Ruminant Research Unit, Faculty of Veterinary Science, Mahasarakham University, Thailand; Network Center for Animal Breeding and Omics Research, Khon Kaen University, Thailand.

2. Faculty of Veterinary Science, Mahasarakham University, Thailand.

3. Applied Animal Physiology Research Unit, Faculty of Veterinary Science, Mahasarakham University, Thailand.

4. Applied Animal Physiology Research Unit, Faculty of Veterinary Science, Mahasarakham University, Thailand; Small Ruminant Research Unit, Faculty of Veterinary Science, Mahasarakham University, Thailand.

Abstract

Background and Aim: Improper attachment of the grounding lead is one of the artifacts and causes difficulty in interpretation of ECG. This study aimed to examine the effects of the position of a ground electrode on electrocardiographic (ECG) parameters in horses. Materials and Methods: Sixteen Arabian horses without any cardiac problems were included in this study. The animals were divided into two groups, the base-apex lead method 1 (BA1 method) and the base-apex lead method 2 (BA2 method) with the reposition of the ground limb electrode to the xiphoid. ECG recordings (paper speed=25 mm/s and calibration=10 mm/ mV) were performed to obtain six limb leads (leads I, II, III, aVR, aVL, and aVF). The amplitude and duration of P waves and QRS complexes, PR interval, QT interval, and T duration were analyzed. T wave morphology was observed. Heart rate was evaluated by using R-R interval in each recording. Results: Heart rate, P duration and amplitude, PR interval and T duration, and QRS duration and amplitude were not significantly different between the BA1 and the BA2 method, except that the BA2 method had a significantly higher QT interval than did the BA1 method (p<0.05). A higher significance of the percentage of coefficient of variation was seen on the P wave amplitude and the ORS amplitude in the BA1 method when compared to BA2 method (p<0.05). Conclusion: These data indicated that base-apex lead method with reposition of the ground limb electrode to the xiphoid can decrease variation of ECG configuration and might be useful for routine ECG evaluation and monitoring in horses. The limitation of this study was the evaluation of cardiac morphology and function by echocardiography to exclude cardiac problems. In further, the studies should examine the effect of breed, age, body weight, and sex on electrocardiography parameters in horses.

Funder

Faculty of Veterinary Science, Mahasarakham University

Publisher

Veterinary World

Subject

General Veterinary