Comparison of computed tomographic ocular biometry in brachycephalic and non-brachycephalic cats
-
Published:2021-03-23
Issue:3
Volume:14
Page:727-733
-
ISSN:2231-0916
-
Container-title:March-2021
-
language:en
-
Short-container-title:Vet World
Author:
Yuwatanakorn Kittiporn1ORCID, Thanaboonnipat Chutimon1ORCID, Tuntivanich Nalinee1ORCID, Darawiroj Damri2ORCID, Choisunirachon Nan1ORCID
Affiliation:
1. Department of Veterinary Surgery, Faculty of Veterinary Science, Chulalongkorn University, Bangkok, Thailand. 2. Department of Veterinary Anatomy, Faculty of Veterinary Science, Chulalongkorn University, Bangkok, Thailand.
Abstract
Background and Aim: Ocular biometry has been used to evaluate ocular parameters; however, several factors need to be considered. In humans, age and sex have been shown to affect ocular biometry. The main factor that affects feline ocular biometry is the head circumference. At present, several reports have revealed that canine ocular biometry differs among dog breeds. However, there are no reports on normal ocular biometry in cats using computed tomography (CT). Therefore, this study aimed to explore feline ocular parameters between brachycephalic (B) and non-brachycephalic (NB) cats using CT and to evaluate the influence of age or sex of cats on ocular biometry.
Materials and Methods: Twenty-four normal cats were divided into two groups: B (n=12) and NB (n=12). Each group had an equal number of designated males and females. CT was performed under mechanical restraint without general anesthesia and intravenous contrast enhancement. Ocular biometry, dimensions of the internal structure, including attenuation numbers and extra-ocular structures, were evaluated and compared.
Results: B-cats had a significantly wider globe width (GW) than NB-cats (p<0.05). In addition, globe length (GL) and GW were significantly correlated with the age of the cats. Significant correlation between GL and age was observed in all cats (r=0.4867; p<0.05), NB-cats (r=0.8692; p<0.05), and B-cats (r=0.4367; p<0.05), whereas the correlation between GW and age was observed in B-cats only (r=0.7251; p<0.05). For extra-ocular structures, NB-cats had significantly greater orbital depth than B-cats (p<0.05), and orbital diameter was significantly correlated with age in all cats and B-cats (p<0.05).
Conclusion: CT can be used for ocular biometric evaluation in cats with different skull types. GW was wider in B-cats, whereas the orbital depth was greater in NB-cats. Moreover, GW, GL, and orbital diameter were affected by the age of the cats. This information will be useful for further ocular diagnosis and treatment, especially in prosthetic surgical procedures.
Publisher
Veterinary World
Subject
General Veterinary
Reference22 articles.
1. La Croix, N.C., van der Woerdt, A. and Olivero, D.K. (2001) Nonhealing corneal ulcers in cats: 29 Cases (1991-1999). J. Am. Vet. Med. Assoc., 218(5): 733-735. 2. Featherstone, H.J. and Sansom, J. (2004) Feline corneal sequestra: A review of 64 cases (80 eyes) from 1993 to 2000. Vet. Ophthalmol., 7(4): 213-227. 3. Gilger, B.C., McLaughlin, S.A., Whitley, R.D. and Wright, J.C. (1992) Orbital neoplasms in cats: 21 Cases (1974-1990). J. Am. Vet. Med. Assoc., 201(7): 1083-1086. 4. Cottrill, N.B., Banks, W.J. and Pechman, R.D. (1989) Ultrasonographic and biometric evaluation of the eye and orbit of dogs. Am. J. Vet. Res., 50(6): 898-903. 5. Salgüero, R., Johnson, V., Williams, D., Hartley, C., Holmes, M., Dennis, R. and Herrtage, M. (2015) CT dimensions, volumes and densities of normal canine eyes. Vet. Rec., 176(15): 386.
Cited by
1 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献
|
|