Evaluation of the Contrast Enhancement Performance of Gadopiclenol for Magnetic Resonance Angiography in Healthy Rabbits and Pigs

Author:

Hugon Gaëlle,Adriaensen Hans,Wintrebert Mélody,Arnould Laurent,Serfaty Jean-Michel,Robert Philippe

Abstract

Objectives Unexpected accumulations of gadolinium in various organs were reported after the administration of gadolinium-based contrast agents, making desirable to reduce the dose while maintaining equivalent diagnostic performance. The aim of this study was to evaluate the contrast enhancement performance of high relaxivity gadopiclenol compared with gadoterate meglumine in abdominal contrast-enhanced magnetic resonance angiography (CE-MRA). Materials and Methods In a first study in healthy rabbits, axial 3D gradient echo sequences were applied at 4.7 T to study arterial enhancement as a function of gadopiclenol dose (0.025, 0.05, 0.075, and 0.1 mmol Gd/kg) or gadoterate meglumine at 0.1 mmol Gd/kg (n = 5–6/group). The increase in signal-to-noise ratio (ΔSNR) in the aorta at the first pass was measured and compared. In a second, crossover study in 6 healthy pigs, abdominal CE-MRA sequences were acquired at 3 T with gadopiclenol at 0.05 mmol Gd/kg or gadoterate meglumine at 0.1 mmol Gd/kg at a 1-week interval. Quantitatively on the maximum intensity projection (MIP) images, the mean MIP SNR within the aorta of both groups was compared. Qualitatively, a blinded comparison of the angiograms was performed by an experienced radiologist to determine the preferred contrast agent. Results In the rabbit, ∆SNR is linearly correlated with the gadopiclenol dose (P = 0.0010). Compared with gadoterate meglumine 0.1 mmol Gd/kg, an increase in the ∆SNR is observed after 0.05, 0.075, and 0.1 mmol Gd/kg of gadopiclenol (+63% P = 0.0731, +78% P = 0.0081, and +72% P = 0.0773, respectively), whereas at 0.025 mmol Gd/kg, ∆SNR is in the same range as with gadoterate meglumine 0.1 mmol Gd/kg (+15% P > 0.9999). In pigs, contrast enhancement after gadopiclenol at 0.05 mmol/kg is +22% superior to MIP SNR after gadoterate meglumine at 0.1 mmol Gd/kg (P = 0.3095). Qualitatively, a preference was shown for gadopiclenol images (3/6) over the gadoterate meglumine examinations (1/6), with no preference being shown for the remainder (2/6). Conclusions First-pass CE-MRA is feasible with gadopiclenol at 0.05 mmol Gd/kg with at least the same arterial signal enhancement and image quality as gadoterate meglumine at 0.1 mmol Gd/kg.

Publisher

Ovid Technologies (Wolters Kluwer Health)

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3