Contrast-Enhanced 3D Spin Echo T1-Weighted Sequence Outperforms 3D Gradient Echo T1-Weighted Sequence for the Detection of Multiple Sclerosis Lesions on 3.0 T Brain MRI

Author:

de Panafieu Ariane,Lecler Augustin1,Goujon Adrien1,Krystal Sidney1,Gueguen Antoine1,Sadik Jean-Claude1,Savatovsky Julien1,Duron Loïc1

Affiliation:

1. Department of Neuroradiology, Hôpital Fondation Adolphe de Rothschild

Abstract

Background Using reliable contrast-enhanced T1 sequences is crucial to detect enhancing brain lesions for multiple sclerosis (MS) at the time of diagnosis and over follow-up. Contrast-enhanced 3D gradient-recalled echo (GRE) T1-weighted imaging (WI) and 3D turbo spin echo (TSE) T1-WI are both available for clinical practice and have never been compared within the context of this diagnosis. Purpose The aim of this study was to compare contrast-enhanced 3D GRE T1-WI and 3D TSE T1-WI for the detection of enhancing lesions in the brains of MS patients. Methods This single-center prospective study enrolled patients with MS who underwent a 3.0 T brain MRI from August 2017 to April 2021 for follow-up. Contrast-enhanced 3D GRE T1-WI and 3D TSE T1-WI were acquired in randomized order. Two independent radiologists blinded to all data reported all contrast-enhanced lesions in each sequence. Their readings were compared with a reference standard established by a third expert neuroradiologist. Interobserver agreement, contrast ratio, and contrast-to-noise ratio were calculated for both sequences. Results A total of 158 MS patients were included (mean age, 40 ± 11 years; 95 women). Significantly more patients had at least 1 contrast-enhanced lesion on 3D TSE T1-WI than on 3D GRE T1-WI for both readers (61/158 [38.6%] vs 48/158 [30.4%] and 60/158 [38.6%] vs 47/158 [29.7%], P < 0.001). Significantly more contrast-enhanced lesions per patient were detected on 3D TSE T1-WI (mean 2.47 vs 1.56 and 2.56 vs 1.39, respectively, P < 0.001). Interobserver agreement was excellent for both sequences, κ = 0.96 (confidence interval [CI], 0.91–1.00) for 3D TSE T1-WI and 0.92 (CI, 0.86–0.99) for 3D GRE T1-WI. Contrast ratio and contrast-to-noise ratio were significantly higher on 3D TSE T1-WI (0.84 vs 0.53, P < 0.001, and 87.9 vs 57.8, P = 0.03, respectively). Conclusions At 3.0 T, contrast-enhanced 3D TSE-T1-WI supports the detection of significantly more enhancing lesions than 3D GRE T1-WI and should therefore be used for MS patients requiring contrast-enhanced examination.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Radiology, Nuclear Medicine and imaging,General Medicine

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3