Contrast Agent Dose Reduction in MRI Utilizing a Generative Adversarial Network in an Exploratory Animal Study

Author:

Haubold Johannes,Jost Gregor1,Theysohn Jens Matthias2,Ludwig Johannes Maximilian2,Li Yan2,Kleesiek Jens3,Schaarschmidt Benedikt Michael2,Forsting Michael2,Nensa Felix,Pietsch Hubertus1,Hosch René

Affiliation:

1. MR and CT Contrast Media Research, Bayer AG, Berlin, Germany.

2. Department of Diagnostic and Interventional Radiology and Neuroradiology, University Hospital Essen, Essen

3. Institute of Artificial Intelligence in Medicine, University Hospital Essen, Essen

Abstract

Objectives The aim of this study is to use virtual contrast enhancement to reduce the amount of hepatobiliary gadolinium-based contrast agent in magnetic resonance imaging with generative adversarial networks (GANs) in a large animal model. Methods With 20 healthy Göttingen minipigs, a total of 120 magnetic resonance imaging examinations were performed on 6 different occasions, 50% with reduced (low-dose; 0.005 mmol/kg, gadoxetate) and 50% standard dose (normal-dose; 0.025 mmol/kg). These included arterial, portal venous, venous, and hepatobiliary contrast phases (20 minutes, 30 minutes). Because of incomplete examinations, one animal had to be excluded. Randomly, 3 of 19 animals were selected and withheld for validation (18 examinations). Subsequently, a GAN was trained for image-to-image conversion from low-dose to normal-dose (virtual normal-dose) with the remaining 16 animals (96 examinations). For validation, vascular and parenchymal contrast-to-noise ratio (CNR) was calculated using region of interest measurements of the abdominal aorta, inferior vena cava, portal vein, hepatic parenchyma, and autochthonous back muscles. In parallel, a visual Turing test was performed by presenting the normal-dose and virtual normal-dose data to 3 consultant radiologists, blinded for the type of examination. They had to decide whether they would consider both data sets as consistent in findings and which images were from the normal-dose study. Results The pooled dynamic phase vascular and parenchymal CNR increased significantly from low-dose to virtual normal-dose (pooled vascular: P < 0.0001, pooled parenchymal: P = 0.0002) and was found to be not significantly different between virtual normal-dose and normal-dose examinations (vascular CNR [mean ± SD]: low-dose 17.6 ± 6.0, virtual normal-dose 41.8 ± 9.7, and normal-dose 48.4 ± 12.2; parenchymal CNR [mean ± SD]: low-dose 20.2 ± 5.9, virtual normal-dose 28.3 ± 6.9, and normal-dose 29.5 ± 7.2). The pooled parenchymal CNR of the hepatobiliary contrast phases revealed a significant increase from the low-dose (22.8 ± 6.2) to the virtual normal-dose (33.2 ± 6.1; P < 0.0001) and normal-dose sequence (37.0 ± 9.1; P < 0.0001). In addition, there was no significant difference between the virtual normal-dose and normal-dose sequence. In the visual Turing test, on the median, the consultant radiologist reported that the sequences of the normal-dose and virtual normal-dose are consistent in findings in 100% of the examinations. Moreover, the consultants were able to identify the normal-dose series as such in a median 54.5% of the cases. Conclusions In this feasibility study in healthy Göttingen minipigs, it could be shown that GAN-based virtual contrast enhancement can be used to recreate the image impression of normal-dose imaging in terms of CNR and subjective image similarity in both dynamic and hepatobiliary contrast phases from low-dose data with an 80% reduction in gadolinium-based contrast agent dose. Before clinical implementation, further studies with pathologies are needed to validate whether pathologies are correctly represented by the network.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Radiology, Nuclear Medicine and imaging,General Medicine

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

1. A New Era in Magnetic Resonance Contrast Media;Investigative Radiology;2023-10-20

2. AI as a New Frontier in Contrast Media Research;Investigative Radiology;2023-10-12

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3