Artifact Reduction From Dental Material in Photon-Counting Detector Computed Tomography Data Sets Based on High-keV Monoenergetic Imaging and Iterative Metal Artifact Reduction Reconstructions—Can We Combine the Best of Two Worlds?

Author:

Risch Franka1,Decker Josua A.1,Popp Daniel1,Sinzinger Andrea1,Braun Franziska1,Bette Stefanie1,Jehs Bertram1,Haerting Mark1,Wollny Claudia1,Scheurig-Muenkler Christian1,Kroencke Thomas J.1,Schwarz Florian

Affiliation:

1. Department of Diagnostic and Interventional Radiology, University Hospital Augsburg, Augsburg

Abstract

Objective The aim of this study was to compare the effectiveness of common strategies for artifact reduction of dental material in photon-counting detector computed tomography data sets. Materials and Methods Patients with dental material who underwent clinically indicated CT of the neck were enrolled. Image series were reconstructed using a standard and sharp kernel, with and without iterative metal artifact reduction (IMAR) (Qr40, Qr40IMAR, Qr60, Qr60IMAR) at different virtual monoenergetic imaging (VMI) levels (40–190 keV). On representative slice positions with and without dental artifacts, mean and standard deviation of CT values were measured in all series at identical locations. The mean absolute error of CT values ( ) and the artifact index (AIX) were calculated and analyzed focusing on 3 main comparisons: (a) different VMI levels versus 70 keV, (b) standard versus sharp kernel, and (c) nonuse or use of IMAR reconstruction. The Wilcoxon test was used to assess differences for nonparametric data. Results The final cohort comprised 50 patients. Artifact measures decreased for VMI levels >70 keV, yet only significantly so for reconstructions using IMAR (maximum reduction, 25%). The higher image noise of the sharp versus standard kernel is reflected in higher AIX values and is more pronounced in IMAR series (maximum increase, 38%). The most profound artifact reduction was observed for IMAR reconstructions (maximum reduction : 84%; AIX: 90%). Conclusions Metal artifacts caused by large amounts of dental material can be substantially reduced by IMAR, regardless of kernel choice or VMI settings. Increasing the keV level of VMI series, on the other hand, only slightly reduces dental artifacts; this effect, however, is additive to the benefit conferred by IMAR reconstructions.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Radiology, Nuclear Medicine and imaging,General Medicine

Reference24 articles.

1. What is the prevalence of various types of prosthetic dental restorations in Europe?;Clin Oral Implants Res,2007

2. Radiopacity of composite dental materials using a digital x-ray system;Dent Mater J,2012

3. Artifacts in magnetic resonance imaging and computed tomography caused by dental materials;PLoS ONE,2012

4. Principles and applications of multienergy CT: report of AAPM task group 291;Med Phys,2020

5. Evaluation of the dental spectral cone beam CT for metal artefact reduction;Dentomaxillofac Radiol,2019

Cited by 7 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献