Assessing the Diagnostic Accuracy of Pulse Pressure Variations for the Prediction of Fluid Responsiveness

Author:

Cannesson Maxime1,Le Manach Yannick2,Hofer Christoph K.3,Goarin Jean Pierre4,Lehot Jean-Jacques5,Vallet Benoît6,Tavernier Benoît6

Affiliation:

1. Associate Professor, Department of Anesthesiology & Perioperative Care, School of Medicine, University of California, Irvine, Irvine, California.

2. Associate Professor, Department of Anesthesiology and Critical Care Medicine, Centre Hospitalier Universitaire Pitié-Salpêtrière, Paris, France, and Centre for Statistics in Medicine, Wolfson College, University of Oxford, Oxford, United Kingdom.

3. Associate Professor, Institute of Anesthesiology and Intensive Care Medicine, Triemli City Hospital, Zurich, Switzerland.

4. Associate Professor, Department of Anesthesiology and Critical Care Medicine, Centre Hospitalier Universitaire Pitié-Salpêtrière.

5. Professor, Department of Anesthesiology and Critical Care, Hôpital Louis Pradel, Lyon, France.

6. Professor, Department of Anesthesiology and Critical Care Medicine, Centre Hospitalier Universitaire de Lille, Lille, France.

Abstract

Background Respiratory arterial pulse pressure variations (PPV) are the best predictors of fluid responsiveness in mechanically ventilated patients during general anesthesia. However, previous studies were performed in a small number of patients and determined a single cutoff point to make clinical discrimination. The authors sought to test the predictive value of PPV in a large, multicenter study and to express it using a gray zone approach. Methods The authors studied 413 patients during general anesthesia and mechanical ventilation in four centers. PPV, central venous pressure, and cardiac output were recorded before and after volume expansion (VE). Response to VE was defined as more than 15% increase in cardiac output after VE. The following approaches were used to determine the gray zones: resampled and two-graph receiver operator characteristic curves. The impact of changes in the benefit-risk balance of VE on the gray zone was also evaluated. Results The authors observed 209 responders (51%) and 204 nonresponders (49%) to VE. The area under receiver operating characteristic curve was 0.89 (95% CI: 0.86-0.92) for PPV, compared with 0.57 (95% CI: 0.54-0.59) for central venous pressure (P < 10). The gray zone approach identified a range of PPV values (between 9% and 13%) for which fluid responsiveness could not be predicted reliably. These PPV values were seen in 98 (24%) patients. Changes in the cost ratio of VE moderately affected the gray zone limits. Conclusion Despite a strong predictive value, PPV may be inconclusive (between 9% and 13%) in approximately 25% of patients during general anesthesia.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Anesthesiology and Pain Medicine

Reference31 articles.

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3