Hemodynamic Effects of Ephedrine, Phenylephrine, and the Coadministration of Phenylephrine with Oxytocin during Spinal Anesthesia for Elective Cesarean Delivery

Author:

Dyer Robert A.1,Reed Anthony R.2,van Dyk Dominique3,Arcache Michelle J.3,Hodges Owen3,Lombard Carl J.4,Greenwood Jaime5,James Michael F.6

Affiliation:

1. Professor.

2. Senior Specialist Anesthesiologist.

3. Specialist Anesthesiologist.

4. Director, Biostatistics Unit, Medical Research Council, Cape Town, South Africa.

5. Specialist Registrar, Nottingham University Hospitals NHS Trust, Nottingham, United Kingdom.

6. Professor and Head, Department of Anesthesia, University of Cape Town, Cape Town, South Africa.

Abstract

Background Hemodynamic responses to vasopressors used during spinal anesthesia for elective Cesarean delivery, have not been well described. This study compared the effects of bolus phenylephrine and ephedrine on maternal cardiac output (CO). The hypothesis was that phenylephrine, but not ephedrine, decreases CO when administered in response to hypotension during spinal anesthesia. Methods Forty-three patients were randomized to receive 80 microg of phenylephrine or 10 mg of ephedrine. Both pulse wave form analysis and transthoracic bioimpedance changes were used to estimate stroke volume in each patient. Hemodynamic responses to spinal anesthesia and oxytocin were also recorded. A subgroup of 20 patients was randomized to receive oxytocin compared with oxytocin plus 80 microg of phenylephrine after delivery. Results Mean CO and maximum absolute response in CO were significantly lower during the 150 s after phenylephrine administration than after ephedrine (6.2 vs. 8.1 l/min, P = 0.001, and 5.2 vs. 9.0 l/min, P < 0.0001, respectively for pulse wave form analysis, and 5.2 vs. 6.3 l/min, P = 0.01 and 4.5 vs. 6.7 l/min, P = 0.0001, respectively for bioimpedance changes). CO changes correlated with heart rate changes. Coadministration of phenylephrine obtunded oxytocin-induced decreases in systemic vascular resistance and increases in heart rate and CO. Trends in CO change were similar using either monitor. Conclusions Bolus phenylephrine reduced maternal CO, and decreased CO when compared with ephedrine during elective spinal anesthesia for Cesarean delivery. CO changes correlated with heart rate changes after vasopressor administration, emphasizing the importance of heart rate as a surrogate indicator of CO. Coadministered phenylephrine obtunded hemodynamic responses to oxytocin.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Anesthesiology and Pain Medicine

Reference22 articles.

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3