Uncalibrated Stroke Volume Variations Are Able to Predict the Hemodynamic Effects of Positive End-Expiratory Pressure in Patients with Acute Lung Injury or Acute Respiratory Distress Syndrome after Liver Transplantation

Author:

Biais Matthieu1,Nouette-Gaulain Karine2,Quinart Alice1,Roullet Stéphanie1,Revel Philippe1,Sztark François3

Affiliation:

1. Staff Anesthesiologist, Department of Anesthesiology and Intensive Care Medicine, Centre Hospitalier Universitaire de Bordeaux.

2. Assistant Professor.

3. Professor of Anesthesiology, Department of Anesthesiology and Intensive Care Medicine, Université Victor Segalen Bordeaux 2 and Centre Hospitalier Universitaire de Bordeaux, Bordeaux, France.

Abstract

Background Positive end-expiratory pressure (PEEP) may reduce cardiac output and total hepatic blood flow after liver transplantation. Pulse pressure variation is useful in predicting the PEEP-induced decrease in cardiac output. The aim of the study was to examine the relationships between stroke volume variations (SVV) obtained with the Vigileo monitor (Edwards Lifesciences, Irvine, CA), and the hemodynamic effects of PEEP. Methods Over 2 yr, patients presenting an acute lung injury or an acute respiratory distress syndrome in the 72 h after liver transplantation were prospectively enrolled. Patients were monitored with a pulmonary artery catheter (stroke volume) and with the Vigileo system (stroke volume and SVV). Measurements were performed in duplicate, first during zero end-expiratory pressure and then 10 min after the addition of 10 cm H2O PEEP. Results Twenty-six patients were included. Six patients were excluded from analysis. On PEEP, SVV and pulse pressure variation increased significantly and stroke volume decreased significantly. PEEP-induced changes in stroke volume measured by pulmonary artery catheter were significantly correlated with SVV (r = 0.69; P < 0.001) and pulse pressure variation on zero end-expiratory pressure (r = 0.66, P < 0.001). PEEP-induced decrease in stroke volume measured by pulmonary artery catheter > or = 15% was predicted by an SVV > 7% (sensitivity = 100%, specificity = 80%) and by a pulse pressure variation > 8% (sensitivity = 80%, specificity = 100%). PEEP-induced changes in stroke volume measured by pulmonary artery catheter and Vigileo device were correlated (r = 0.51, P < 0.005). Conclusions SVV obtained with Vigileo monitor is useful to predict decrease in stroke volume induced by PEEP. Moreover, this device is able to track changes in stroke volume induced by PEEP.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Anesthesiology and Pain Medicine

Reference58 articles.

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3