Is the Performance of Acceleromyography Improved with Preload and Normalization?

Author:

Claudius Casper1,Skovgaard Lene Theil2,Viby-Mogensen Jørgen3

Affiliation:

1. Research Assistant.

2. Associate Professor, Department of Biostatistics, Copenhagen University, Denmark.

3. Professor, Department of Anaesthesia, Centre of Head and Orthopaedics, Copenhagen University Hospital, Rigshospitalet, Denmark.

Abstract

Background Many studies have indicated that acceleromyography and mechanomyography cannot be used interchangeably. To improve the agreement between the two methods, it has been suggested to use a preload and to refer all train-of-four (TOF) ratios to the control TOF (normalization) when using acceleromyography. The first purpose of this study was to test whether a preload applied to acceleromyography would increase the precision and the agreement with mechanomyography. The second purpose was to evaluate whether normalization would improve the agreement with mechanomyography. Methods Sixty patients were randomized to acceleromyography with or without a preload (Hand Adapter; Organon, Oss, the Netherlands). On the contralateral arm, mechanomyography was used. Anesthesia was induced with propofol and an opioid, and neuromuscular block with 0.6 mg/kg rocuronium. The precision and the bias and limits of agreement (with or without normalization) between the methods were evaluated using TOF stimulation. Results Preload improved the precision of acceleromyography by 21%, but it also increased the mean control TOF ratio from 1.07 to 1.13. Normalization of the acceleromyographic TOF ratios diminished the bias to mechanomyography during recovery (e.g., from 0.15 to 0.05 at TOF 0.90); when the mechanomyographic TOF values were normalized as well, the bias was eliminated. However, normalization did not exclude wide individual differences between acceleromyography and mechanomyography (+/- 0.10-0.20 at TOF 0.90). Conclusion Preload increases the precision of acceleromyography, and normalization of the TOF ratios decreases bias in relation to mechanomyography. When both acceleromyography and mechanomyography are normalized, there is no significant bias between the two methods.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Anesthesiology and Pain Medicine

Reference32 articles.

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3