Comparison of Two Doses of Tranexamic Acid in Adults Undergoing Cardiac Surgery with Cardiopulmonary Bypass

Author:

Sigaut Stéphanie1,Tremey Benjamin1,Ouattara Alexandre1,Couturier Roland1,Taberlet Christian1,Grassin-Delyle Stanislas1,Dreyfus Jean-Francois1,Schlumberger Sylvie1,Fischler Marc1

Affiliation:

1. From the Department of Anesthesiology (S.Sigaut, B.T., S. Schlumberger, M.F.), Clinical Research Unit (J.-F.D.), Hôpital Foch, Suresnes, France; Department of Anesthesiology and Critical Care 2 (A.O.), University Hospital, Bordeaux, France; Department of Anesthesiology, Centre Chirurgical Marie Lannelongue (R.C.), Le Plessis-Robinson, France; Department of Anesthesiology and Critical Care (C.T.),

Abstract

Abstract Background: The optimal dose of tranexamic acid (TA) is still an issue. The authors compared two doses of TA during cardiac surgery in a multicenter, double-blinded, randomized study. Methods: Patients were stratified according to transfusion risk, then randomized to two TA doses: 10 mg/kg bolus followed by 1 mg·kg−1·h−1 infusion (low dose) until the end of surgery or 30 mg/kg bolus followed by 16 mg·kg−1·h−1 infusion (high dose). The primary endpoint was the incidence of blood product transfusion up to day 7. Secondary ones were incidences of transfusion for each type of blood product and amounts transfused, blood loss, repeat surgery, TA-related adverse events, and mortality. Results: The low-dose group comprised 284 patients and the high-dose one 285. The primary endpoint was not significantly different between TA doses (63% for low dose vs. 60% for high dose; P = 0.3). With the high dose, a lower incidence of frozen plasma (18 vs. 26%; P = 0.03) and platelet concentrate (15 vs. 23%; P = 0.02) transfusions, lower amounts of blood products (2.5 ± 0.38 vs. 4.1 ± 0.39; P = 0.02), fresh frozen plasma (0.49 ± 0.14 vs.1.07 ± 0.14; P = 0.02), and platelet concentrates transfused (0.50 ± 0.15 vs. 1.13 ± 0.15; P = 0.02), lower blood loss (590 ± 50.4 vs. 820 ± 50.7; P = 0.01), and less repeat surgery (2.5 vs. 6%; P = 0.01) were observed. These results are more marked in patients with a high risk for transfusion. Conclusions: A high dose of TA does not reduce incidence of blood product transfusion up to day 7, but is more effective than a low dose to decrease transfusion needs, blood loss, and repeat surgery.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Anesthesiology and Pain Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3