Prospective Clinical and Fiberoptic Evaluation of the Supreme Laryngeal Mask Airway ™

Author:

Timmermann Arnd1,Cremer Stefan2,Eich Christoph1,Kazmaier Stephan1,Bräuer Anselm1,Graf Bernhard M.3,Russo Sebastian G.1

Affiliation:

1. Staff Anesthesiologist.

2. Resident in Anesthesiology.

3. Professor of Anesthesiology, Department of Anesthesiology, Emergency and Intensive Care Medicine, University Medical Center, Göttingen, Germany.

Abstract

Background In March 2007, a new disposable laryngeal mask airway (LMA) became available. The LMA Supreme (The Laryngeal Mask Company Limited, St. Helier, Jersey, Channel Islands) aims to combine the LMA Fastrach feature of easy insertion with the gastric access and high oropharyngeal leak pressures of the LMA ProSeal. Methods The authors performed an evaluative study with the LMA Supreme, size 4, on 100 women to measure the ease of insertion, determinate the laryngeal fit by fiberoptic classification, evaluate the oropharyngeal leak pressure, and report adverse events. Results Insertion of the LMA Supreme was possible in 94 patients (94%) during the first attempt, and in 5 patients (5%) during the second attempt. In one small patient, the LMA Supreme could not be inserted because of limited pharyngeal space. This patient was excluded from further analysis. Insertion of a gastric tube was possible in all patients at the first attempt. The median time for LMA Supreme insertion was 10.0 s (+/-4.7 s; range, 8-30 s). Laryngeal fit, evaluated by fiberscopic view, was rated as optimal in all patients, both immediately after insertion of the LMA Supreme and at the end of surgery. After equalization to room pressure, the mean cuff volume needed to achieve 60 cm H2O cuff pressure was 18.4 ml (+/-3.8 ml; range, 8-31 ml). The mean oropharyngeal leak pressure at the level of 60 cm H2O cuff pressure was 28.1 cm H2O (+/-3.8 cm H2O, range, 21-35 cm H2O). Eight patients (8.1%) complained of a mild sore throat. No patient reported dysphagia or dysphonia. Conclusions Clinical evaluation of the LMA Supreme showed easy insertion, optimal laryngeal fit, and low airway morbidity. Oropharyngeal leak pressure results were comparable to earlier data from the LMA ProSeal.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Anesthesiology and Pain Medicine

Reference13 articles.

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3