EVALUATION OF THE INCLUSION OF SPECTRAL DOMAIN OPTICAL COHERENCE TOMOGRAPHY IN A TELEMEDICINE DIABETIC RETINOPATHY SCREENING PROGRAM

Author:

Arruabarrena Carolina1,Rodríguez-Miguel Antonio2,Allendes Germán1,Vera Carlos1,Son Beatriz1,Teus Miguel A.13

Affiliation:

1. Department of Ophthalmology, University Hospital “Príncipe de Asturias”, Alcalá de Henares, Madrid, Spain;

2. Department of Biomedical Sciences, University of Alcalá (IRYCIS), Alcalá de Henares, Madrid, Spain; and

3. Ophthalmology Unit, Department of Surgery Medical and Social Sciences, Universidad de Alcalá. Alcalá de Henares, Madrid, Spain.

Abstract

Purpose: To evaluate whether combining spectral domain optical coherence tomography with monoscopic fundus photography using a nonmydriatic camera (MFP-NMC) improves the accuracy of diabetic macular edema (DME) referrals in a teleophthalmology diabetic retinopathy screening program. Methods: We conducted a cross-sectional study with all diabetic patients aged 18 years or older who attended screening from September 2016 to December 2017. We assessed DME according to the three MFP-NMC and the four spectral domain optical coherence tomography criteria. The sensitivity and specificity obtained for each criterion were estimated by comparing them with the ground truth of DME. Results: This study included 3,918 eyes (1,925 patients; median age, 66 years; interquartile range, 58–73; females, 40.7%; once-screened, 68.1%). The prevalence of DME ranged from 1.22% to 1.83% and 1.54% to 8.77% on MFP-NMC and spectral domain optical coherence tomography, respectively. Sensitivity barely reached 50% in MFP-NMC and less for the quantitative criteria of spectral domain optical coherence tomography. When macular thickening and anatomical signs of DME were considered, sensitivity increased to 88.3% and the false DMEs and non-gradable images were reduced. Conclusion: Macular thickening and anatomical signs showed the highest suitability for screening, with a sensitivity of 88.3% and a specificity of 99.8%. Notably, MFP-NMC alone missed half of the true DMEs that lacked indirect signs.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Ophthalmology,General Medicine

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3