Higher Frequency Ventilation Attenuates Lung Injury during High-frequency Oscillatory Ventilation in Sheep Models of Acute Respiratory Distress Syndrome

Author:

Liu Songqiao1,Yi Yang2,Wang Maohua1,Chen Qiuhua1,Huang Yingzi1,Liu Ling1,Xie Jianfeng1,Zhou Dunyuan3,Qiu Haibo4

Affiliation:

1. Staff Intensivist

2. Associate Professor, Staff Intensivist

3. Master’s Student, Institute of Medical Science, University of Toronto, Toronto, Ontario, Canada.

4. Professor and Chair, Department of Critical Care Medicine, Nanjing Zhongda Hospital, School of Medical, Southeast University, Nanjing, Jiangsu, P. R. China.

Abstract

Abstract Background: High-frequency oscillatory ventilation (HFOV) at higher frequencies minimizes the tidal volume. However, whether increased frequencies during HFOV can reduce ventilator-induced lung injury remains unknown. Methods: After the induction of acute respiratory distress syndrome in the model by repeated lavages, 24 adult sheep were randomly divided into four groups (n = 6): three HFOV groups (3, 6, and 9 Hz) and one conventional mechanical ventilation (CMV) group. Standard lung recruitments were performed in all groups until optimal alveolar recruitment was reached. After lung recruitment, the optimal mean airway pressure or positive end-expiratory pressure was determined with decremental pressure titration, 2 cm H2O every 10 min. Animals were ventilated for 4 h. Results: After lung recruitment, sustained improvements in gas exchange and compliance were observed in all groups. Compared with the HFOV-3 Hz and CMV groups, the transpulmonary pressure and tidal volumes were statistically significantly lower in the HFOV-9 Hz group. The lung injury scores and wet/dry weight ratios were significantly reduced in the HFOV-9 Hz group compared with the HFOV-3 Hz and CMV groups. Expression of interleukin-1β and interleukin-6 in the lung tissue, decreased significantly in the HFOV-9 Hz group compared with the HFOV-3 Hz and CMV groups. Malondialdehyde expression and myeloperoxidase activity in lung tissues in the HFOV-9 Hz group decreased significantly, compared with the HFOV-3 Hz and CMV groups. Conclusion: The use of HFOV at 9 Hz minimizes lung stress and tidal volumes, resulting in less lung injury and reduced levels of inflammatory mediators compared with the HFOV-3 Hz and CMV conditions.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Anesthesiology and Pain Medicine