Dependence of Cochlear Duct Length Measurement on the Resolution of the Imaging Dataset

Author:

Spahn Bjoern1,Ilgen Lukas1,Neun Tilmann2,Müller-Graff Franz-Tassilo1,Schendzielorz Philipp1,Hagen Rudolf1,Althoff Daniel3,Zabler Simon4,Rak Kristen1

Affiliation:

1. Department of Oto-Rhino-Laryngology, Plastic, Aesthetic and Reconstructive Head and Neck Surgery and the Comprehensive Hearing Center

2. Institute for Diagnostic and Interventional Neuroradiology, University of Wuerzburg

3. Fraunhofer Development Center for X-ray Technology, Wuerzburg

4. Deggendorf Institute of Technology, Faculty of Applied Computer Science, Deggendorf, Germany

Abstract

Hypothesis Measurements of the cochlear duct length (CDL) are dependent on the resolution of the imaging dataset. Background Previous research has shown highly precise cochlear measurements using 3D-curved multiplanar reconstruction (MPR) and flat-panel volume computed tomography (fpVCT). Thus far, however, there has been no systematic evaluation of the imaging dataset resolution required for optimal CDL measurement. Therefore, the aim of this study was to evaluate the dependence of CDL measurement on the resolution of the imaging dataset to establish a benchmark for future CDL measurements. Methods fpVCT scans of 10 human petrous bone specimens were performed. CDL was measured using 3D-curved MPR with secondary reconstruction of the fpVCT scans (fpVCTSECO) and increasing resolution from 466 to 99 μm. In addition, intraobserver variability was evaluated. A best-fit function for calculation of the CDL was developed to provide a valid tool when there are no measurements done with high-resolution imaging datasets. Results Comparison of different imaging resolution settings showed significant differences for CDL measurement in most of the tested groups (p < 0.05), except for the two groups with the highest resolution. Imaging datasets with a resolution lower than 200 μm showed lower intraobserver variability than the other resolution settings, although there were no clinically unacceptable errors with respect to the Bland-Altman plots. The developed best-fit function showed high accuracy for CDL calculation using resolution imaging datasets of 300 μm or lower. Conclusion 3D-curved MPR in fpVCT with a resolution of the imaging dataset of 200 μm or higher revealed the most precise CDL measurement. There was no benefit of using a resolution higher than 200 μm with regard to the accuracy of the CDL measurement.

Publisher

Ovid Technologies (Wolters Kluwer Health)

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3