Abstract

Background Anatomy-based fitting (ABF) is a new research area in the field of cochlear implants (CIs). Despite the reported benefits and acceptable levels of ABF among CI recipients, some limitations remain, like the postoperative computed tomography (CT) scan, which is preferred for confirming electrode array insertion. Objective This study aimed to investigate the feasibility of using plain film radiography (X-ray) for postoperative electrode detection and for building ABF as an alternative to CT. Methods A total of 53 ears with CI were studied. All cases had routine post-insertion X-rays in the cochlear view and additionally underwent postoperative CT. The insertion angles and center frequencies measured by two independent observers were compared for each imaging modality. The angular insertion depth and center frequencies resulting from the X-ray and CT scans were then compared. Results No significant differences were observed between the X-ray– and CT-measured angles for the electrode contacts. Radiographic measurements between the two readers showed an almost perfect (≥0.8) or substantial (0.71) intraclass correlation coefficient along the electrode contacts. X-ray images showed a mean difference of 4.7 degrees from CT. The mean semitone deviation of the central frequency between the CT and X-ray images was 0.6. Conclusions X-ray imaging provides a valid and easy-to-perform alternative to CT imaging, with less radiation exposure and lower costs. The radiographs showed excellent concordance with the CT-measured angular insertion depth and consequently with the central frequency for most electrode contacts. Therefore, plain X-ray could be a viable alternative in building ABF for the CI recipients.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Neurology (clinical),Sensory Systems,Otorhinolaryngology

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3