Diagnostic Efficacy of High-Resolution Computed Tomography Densitometry for Diagnosing Otosclerosis

Author:

Puiggrós Ignacio Viza1,Moreno Esther Granell2,Dotu César Orús3,Agustí Miquel Quer i3,Díaz Francesc Larrosa

Affiliation:

1. Department of Otorhinolaryngology-Head and Neck Surgery, Hospital Clinic de Barcelona

2. Neuroradiology Department, UDIAT-Parc Taulí, Sabadell

3. Division of Otology, Department of Otolaryngology, Hospital de la Santa Creu i Sant Pau

Abstract

Objectives The purpose of this study is to evaluate the reliability of temporal bone density measurements for diagnosing otosclerosis. Materials and methods A retrospective case-control study is presented. Bone density was measured in Hounsfield units (HUs) by using high-resolution computed tomography in eight regions of interest (ROI) where otosclerotic foci are usually localized. The density of 113 otosclerotic ears was compared with that of 33 nonotosclerotic ears to determine sensitivity and specificity. Furthermore, the binormal receiver operating characteristic curve of each ROI's density was calculated to estimate the diagnostic value for osteosclerosis. In addition, the radiological density of seven cases—where radiological visual examination exhibited no findings but surgery confirmed stapes fixation—was compared with nonotosclerotic controls. Results ROI densities were significantly lower in otosclerotic patients compared with nonotosclerotic controls. The area under the curve of the fissula ante fenestram (FAF) presented the highest diagnostic performance: 1,871 HU cut-off value (area under the curve = 0.986), 96.64% sensitivity, and 100% specificity. Significantly lower densities in the FAF area were observed in the seven cases with negative radiology but intraoperatively confirmed otosclerosis. Conclusion The high-resolution computed tomography density of the FAF is a reliable measurement for diagnosing otosclerosis. A value less than 1,871 HU exhibited the highest sensitivity and specificity in a European Caucasian population.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Neurology (clinical),Sensory Systems,Otorhinolaryngology

Reference22 articles.

1. Why do we include CT scanning in the evaluation of otosclerosis patients?;ORL J Otorhinolaryngol Relat Spec,2010

2. High-resolution computed tomography in the diagnosis of otosclerosis in Taiwan;J Chin Med Assoc,2009

3. Computed tomography in the diagnosis of otosclerosis;Otolaryngol Head Neck Surg,2006

4. Fenestral otosclerosis: significance of preoperative CT evaluation;Radiology [Internet],1984

5. CT densitometry of the cochlear capsule in otosclerosis;Am J Neuroradiol,1985

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3