Post Cochlear Implantation Vertigo: Ictal Nystagmus and Audiovestibular Test Characteristics

Author:

Kwok Belinda Y. C.,Young Allison S.,Kong Jonathan H. K.,Birman Catherine S.,Flanagan Sean1,Greenberg Simon L.2,Gibson William P.3,Argaet Emma C.,Fratturo Luke,Pogson Jacob M.,Taylor Rachael L.,Rosengren Sally M.,Halmagyi G. Michael,Welgampola Miriam S.

Affiliation:

1. Department of Otolaryngology, Head and Neck, and Skull Base Surgery, St Vincent's Public Hospital, Sydney

2. Ear, Nose and Throat Surgery, St George Hospital, Kogarah

3. NextSense, Gladesville

Abstract

Objective To investigate ictal nystagmus and audiovestibular characteristics in episodic spontaneous vertigo after cochlear implantation (CI). Study Design Retrospective and prospective case series. Patients Twenty-one CI patients with episodic spontaneous vertigo after implantation were recruited. Interventions Patient-initiated home video-oculography recordings were performed during one or more attacks of vertigo, using miniature portable home video-glasses. To assess canal and otolith function, video head-impulse tests (vHITs) and vestibular-evoked myogenic potential tests were conducted. Main Outcome Measures Nystagmus slow-phase velocities (SPVs), the presence of horizontal direction-changing nystagmus, and post-CI audiovestibular tests. Results Main final diagnoses were post-CI secondary endolymphatic hydrops (48%) and exacerbation of existing Ménière's disease (29%). Symptomatic patients demonstrated high-velocity horizontal ictal-nystagmus (SPV, 44.2°/s and 68.2°/s in post-CI secondary endolymphatic hydrop and Ménière's disease). Direction-changing nystagmus was observed in 80 and 75%. Two were diagnosed with presumed autoimmune inner ear disease (SPV, 6.6°/s and 172.9°/s). One patient was diagnosed with probable vestibular migraine (15.1°/s). VHIT gains were 0.80 ± 0.20 (lateral), 0.70 ± 0.17 (anterior), and 0.62 ± 0.27 (posterior) in the implanted ear, with abnormal values in 33, 35, and 35% of each canal. Bone-conducted cervical and ocular vestibular-evoked myogenic potentials were asymmetric in 52 and 29% of patients (all lateralized to the implanted ear) with mean asymmetry ratios of 51.2 and 35.7%. Reversible reduction in vHIT gain was recorded in three acutely symptomatic patients. Conclusion High-velocity, direction-changing nystagmus time-locked with vertigo attacks may be observed in post-CI implant vertigo and may indicate endolymphatic hydrops. Fluctuating vHIT gain may be an additional marker of a recurrent peripheral vestibulopathy.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Neurology (clinical),Sensory Systems,Otorhinolaryngology

Reference37 articles.

1. Meta-analysis of subjective complaints of vertigo and vestibular tests after cochlear implantation;Laryngoscope,2018

2. Different forms of dizziness occurring after cochlear implant;Eur Arch Otorhinolaryngol,2001

3. Prevalence of new-onset vestibular symptoms following cochlear implantation;J Otolaryngol Head Neck Surg,2008

4. Influence of the multichannel cochlear implant on vestibular function;Otolaryngol Head Neck Surg,1998

5. Patients reported outcome post-cochlear implantation: How severe is their dizziness?;J Otolaryngol Head Neck Surg,2014