Long-Term Hearing Outcomes After Hybrid Cochlear Implantation

Author:

Salmon Mandy K.1,Quimby Alexandra E.1,Bartellas Michael2,Kaufman Hannah S.3,Bigelow Douglas C.1,Brant Jason A.4,Ruckenstein Michael J.1

Affiliation:

1. Department of Otorhinolaryngology–Head and Neck Surgery, University of Pennsylvania, Philadelphia, Pennsylvania, USA

2. Department of Otolaryngology, University of Ottawa, Ottawa, Ontario, Canada

3. Department of Audiology, University of Pennsylvania

4. Corporal Michael J. Crescenz Veterans Affairs Medical Center, Philadelphia, Pennsylvania, USA

Abstract

Objective To examine long-term (>5 yr) low-frequency hearing preservation after hybrid cochlear implantation. Study Design Retrospective cross-sectional study. Setting Tertiary care center outpatient clinic. Patients All patients older than 21 years implanted with a Cochlear Hybrid L24 device from 2014 to 2021. Main Outcome Measure Changes in low-frequency pure-tone average (LFPTA) were calculated at each of several time points relative to the date of implantation. The proportion of patients with preserved LFPTA at last follow-up and Kaplan-Meier estimates for loss of residual hearing were calculated in addition to hazard ratios for hearing loss according to patient- and surgery-specific factors. Results Thirty ears in 29 patients underwent hybrid cochlear implantation and were eligible for inclusion (mean age, 59 yr; 65% female). Mean preoperative LFPTA was 31.7 dB. Mean LFPTA across all implanted ears at first follow-up was 45.1 dB; no patient had experienced loss of residual hearing at first follow-up. Six patients had loss of residual hearing during the follow-up period, with Kaplan-Meier probability estimates of preserved hearing of 100% at 1 month, 90% at 12 months, 87% at 24 months, and 80% at 48 months. There was no association between loss of residual hearing and patient age, preoperative LFPTA, surgeon, or use of topical steroids intraoperatively (hazard ratios, 1.05 [0.96–1.15], 0.97 [0.88–1.05], 1.39 [0.20–9.46], 0.93 [0.09–9.74], respectively). Conclusions Long-term (>5 yr) outcomes after hybrid cochlear implantation demonstrate good preservation of low-frequency hearing, with only modest decline in the long-term postimplantation, and a low proportion of loss of residual low-frequency hearing.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Neurology (clinical),Sensory Systems,Otorhinolaryngology

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3