Transimpedance Matrix Can Be Used to Estimate Electrode Positions Intraoperatively and to Monitor Their Positional Changes Postoperatively in Cochlear Implant Patients

Author:

Zhang Lichun1,Schmidt Florian Herrmann1,Oberhoffner Tobias1,Ehrt Karsten1,Cantré Daniel2,Großmann Wilma1,Schraven Sebastian P.1,Mlynski Robert1

Affiliation:

1. Departments of Otorhinolaryngology, Head and Neck Surgery, “Otto Körner,” and

2. Radiology, Rostock University Medical Center, Rostock, Germany

Abstract

Objective Accurate positioning of the electrode array during cochlear implant (CI) surgery is crucial for achieving optimal hearing outcomes. Traditionally, postoperative radiological imaging has been used to assess electrode position. Transimpedance matrix (TIM) measurements have also emerged as a promising method for assessing electrode position. This involves utilizing electric field imaging to create an electric distance matrix by analyzing voltage variations among adjacent electrodes. This study aimed to investigate the feasibility of using intraoperative TIM measurements to estimate electrode position and monitor postoperative changes. Study Design Retrospective cohort study. Setting University Medical center, tertiary academic referral center. Patients Patients undergoing CI (CI622) surgery between January 2019 and June 2022. Intervention CI electrode positions and maximal angular insertion depths (maxAID) were determined using X-ray imaging according to Stenvers' projection. The mean gradient phase (MGP) was extracted from the TIM, and a correlation between the MGP and maxAID was examined. A model was then built to estimate the maxAID using the MGP, and changes in electrode location over time were assessed using this model. Main Outcome Measures Twenty-four patients were included in this study. A positive correlation between the maxAID and the MGP (R = 0.7, p = 0.0001) was found. The established model was able to predict the maxAID with an accuracy of 27.7 ± 4.4°. Comparing intraoperative and postoperative TIM measurements, a decrease of 24.1° ± 10.7° in maxAID over time was observed. Conclusion TIM measurements are useful for estimating the insertion depth of the electrode and monitoring changes in the electrode's position over time.

Publisher

Ovid Technologies (Wolters Kluwer Health)

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3