Pipeline for Automated Processing of Clinical Cone-Beam Computed Tomography for Patient-Specific Temporal Bone Simulation: Validation and Clinical Feasibility

Author:

Andersen Steven Arild Wuyts,Hittle Brad1,Keith Jason P.1,Powell Kimerly A.1,Wiet Gregory J.

Affiliation:

1. Department of Biomedical Informatics, The Ohio State University, Columbus, Ohio

Abstract

Objective Patient-specific simulation allows the surgeon to plan and rehearse the surgical approach ahead of time. Preoperative clinical imaging for this purpose requires time-consuming manual processing and segmentation of landmarks such as the facial nerve. We aimed to evaluate an automated pipeline with minimal manual interaction for processing clinical cone-beam computed tomography (CBCT) temporal bone imaging for patient-specific virtual reality (VR) simulation. Study Design Prospective image processing of retrospective imaging series. Setting Academic hospital. Methods Eleven CBCTs were selected based on quality and used for validation of the processing pipeline. A larger naturalistic sample of 36 CBCTs were obtained to explore parameters for successful processing and feasibility for patient-specific VR simulation. Visual inspection and quantitative metrics were used to validate the accuracy of automated segmentation compared with manual segmentation. Range of acceptable rotational offsets and translation point selection variability were determined. Finally, feasibility in relation to image acquisition quality, processing time, and suitability for VR simulation was evaluated. Results The performance of automated segmentation was acceptable compared with manual segmentation as reflected in the quantitative metrics. Total time for processing for new data sets was on average 8.3 minutes per data set; of this, it was less than 30 seconds for manual steps. Two of the 36 data sets failed because of extreme rotational offset, but overall the registration routine was robust to rotation and manual selection of a translational reference point. Another seven data sets had successful automated segmentation but insufficient suitability for VR simulation. Conclusion Automated processing of CBCT imaging has potential for preoperative VR simulation but requires further refinement.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Neurology (clinical),Sensory Systems,Otorhinolaryngology

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司