A Multicenter Comparison of 1-yr Functional Outcomes and Programming Differences Between the Advanced Bionics Mid-Scala and SlimJ Electrode Arrays

Author:

Eitutis Susan T.,Vickers Deborah A.1,Tebbutt Karen2,Thomas Tisa2,Jiang Dan2,de Klerk Anel2,Clemesha Jennifer3,Chung Mark3,Bance Manohar L.4

Affiliation:

1. Sound Laboratory, Cambridge Hearing Group, Clinical Neurosciences, University of Cambridge, Cambridge

2. Guy's and St. Thomas' NHS Foundation Trust

3. Auditory Implant Department, Royal National ENT & Eastman Dental Hospitals, University College London Hospitals NHS Foundation Trust, London, United Kingdom

4. Cambridge Hearing Group, Department of Clinical Neurosciences, Cambridge Biomedical Campus, University of Cambridge

Abstract

Objective To determine if there is a difference in hearing outcomes or stimulation levels between Advanced Bionics straight and precurved arrays. Study design Retrospective chart review across three implant centers. Setting Tertiary centers for cochlear and auditory brainstem implantation. Patients One hundred fifteen pediatric and 205 adult cochlear implants (CIs) were reviewed. All patients were implanted under the National Institute for Health and Care Excellence 2009 guidelines with a HiRes Ultra SlimJ or Mid-Scala electrode array. Main outcome measures Hearing preservation after implantation, as well as CI-only listening scores for Bamford-Kowal-Bench sentences were compared 1 year after implantation. Stimulation levels for threshold and comfort levels were also compared 1 year after implantation. Results Hearing preservation was significantly better with the SlimJ compared with the Mid-Scala electrode array. Bamford-Kowal-Bench outcomes were not significantly different between the two arrays in any listening condition. Stimulation levels were not different between arrays but did vary across electrode contacts. At least one electrode was deactivated in 33% of implants but was more common for the SlimJ device. Conclusion Modern straight and precurved arrays from Advanced Bionics did not differ in hearing performance or current requirements. Although hearing preservation was possible with both devices, the SlimJ array would still be the preferred electrode in cases where hearing preservation was a priority. Unfortunately, the SlimJ device was also prone to poor sound perception on basal electrodes. Further investigation is needed to determine if deactivated electrodes are associated with electrode position/migration, and if programming changes are needed to optimize the use of these high-frequency channels.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Neurology (clinical),Sensory Systems,Otorhinolaryngology

Reference66 articles.

1. Relationship between electrode-to-modiolus distance and current levels for adults with cochlear implants;Otol Neurotol,2016

2. Threshold, comfortable level and impedance changes as a function of electrode-modiolar distance;Ear Hear,2002

3. Psychophysics of a prototype peri-modiolar cochlear implant electrode array;Hear Res,2001

4. An overview of cochlear implant electrode array designs;Hear Res,2017

5. Factors affecting open-set word recognition in adults with cochlear implants;Ear Hear,2013

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3