Pilot study of a pedestrian collision detection test for a multisite trial of field expansion devices for hemianopia

Author:

Bowers Alex R.,Manda Sailaja1,Shekar Sandhya1,Hwang Alex D.1,Jung Jae-Hyun1,Peli Eli1

Affiliation:

1. Schepens Eye Research Institute of Mass Eye and Ear, Department of Ophthalmology, Harvard Medical School, Boston, Massachusetts

Abstract

SIGNIFICANCE Performance-based outcome measures are crucial for clinical trials of field expansion devices. We implemented a test simulating a real-world mobility situation, focusing on detection of a colliding pedestrian among multiple noncolliding pedestrians, suitable for measuring the effects of homonymous hemianopia and assistive devices in clinical trials. PURPOSE In preparation for deploying the test in a multisite clinical trial, we conducted a pilot study to gather preliminary data on blind-side collision detection performance with multiperiscopic peripheral prisms compared with Fresnel peripheral prisms. We tested the hypothesis that detection rates for colliding pedestrians approaching on a 40° bearing angle (close to the highest collision risk when walking) would be higher with 100Δ oblique multiperiscopic (≈42° expansion) than 65Δ oblique Fresnel peripheral prisms (≈32° expansion). METHODS Six participants with homonymous hemianopia completed the test with and without each type of prism glasses, after using them in daily mobility for a minimum of 4 weeks. The test, presented as a video on a large screen, simulated walking through a busy shopping mall. Colliding pedestrians approached from the left or the right on a bearing angle of 20 or 40°. RESULTS Overall, blind-side detection was only 23% without prisms but improved to 73% with prisms. For multiperiscopic prisms, blind-side detection was significantly higher with than without prisms at 40° (88 vs. 0%) and 20° (75 vs. 0%). For Fresnel peripheral prisms, blind-side detection rates were not significantly higher with than without prisms at 40° (38 vs. 0%) but were significantly higher with prisms at 20° (94 vs. 56%). At 40°, detection rates were significantly higher with multiperiscopic than Fresnel prisms (88 vs. 38%). CONCLUSIONS The collision detection test is suitable for evaluating the effects of hemianopia and prism glasses on collision detection, confirming its readiness to serve as the primary outcome measure in the upcoming clinical trial.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3