Wearable apparatus for correction of visual alignment under torsional strabismus

Author:

Malleson Charles,Guillemaut Jean-Yves1

Affiliation:

1. Centre for Vision, Speech and Signal Processing, University of Surrey, United Kingdom

Abstract

SIGNIFICANCE A wearable optical apparatus that compensates for eye misalignment (strabismus) to correct for double vision (diplopia) is proposed. In contrast to prism lenses, commonly used to compensate for horizontal and/or vertical misalignment, the proposed approach is able to compensate for any combination of horizontal, vertical, and torsional misalignment. PURPOSE If the action of the extraocular muscles is compromised (e.g., by nerve damage), a patient may lose their ability to maintain visual alignment, negatively affecting their binocular fusion and stereo depth perception capability. Torsional misalignment cannot be mitigated by standard Fresnel prism lenses. Surgical procedures intended to correct torsional misalignment may be unpredictable. A wearable device able to rectify visual alignment and restore stereo depth perception without surgical intervention could potentially be of great value to people with strabismus. METHODS We propose a novel lightweight wearable optical device for visual alignment correction. The device comprises two mirrors and a Fresnel prism, arranged in such a way that together they rotationally shift the view seen by the affected eye horizontally, vertically, and torsionally. The extent of the alignment correction on each axis can be arbitrarily adjusted according to the patient's particular misalignment characteristics. RESULTS The proposed approach was tested by computer simulation, and a prototype device was manufactured. The prototype device was tested by a strabismus patient exhibiting horizontal and torsional misalignment. In these tests, the device was found to function as intended, allowing the patient to enjoy binocular fusion and stereo depth perception while wearing the device for daily activities over a period of several months. CONCLUSIONS The proposed device is effective in correcting arbitrary horizontal, vertical, and torsional misalignment of the eyes. The results of the initial testing performed are highly encouraging. Future study is warranted to formally assess the effectiveness of the device on multiple test patients.

Publisher

Ovid Technologies (Wolters Kluwer Health)

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3