Affiliation:
1. Noor Ophthalmology Research Center, Noor Eye Hospital, Tehran, Iran
2. Department of Basic Sciences, School of Nursing and Midwifery, Shahid Beheshti University of Medical Sciences, Tehran, Iran
Abstract
ABSTRACT
SIGNIFICANCE
The anterior chamber depth in hyperopic eyes is significantly deeper than that in myopic eyes, and this finding is independent of the axial length.
PURPOSE
This study aimed to determine the relationship between and refractive errors and ocular biometric components in a geriatric population 60 years and older.
METHODS
The present population-based cross-sectional study was performed using a multistage random cluster sampling method in Tehran, Iran. After selecting the samples, visual acuity measurement, autorefraction, subjective refraction, and slit-lamp examination were performed for all participants. Ocular biometric indices were measured with Pentacam AXL (Oculus, Wetzlar, Germany).
RESULTS
The correlation coefficients of spherical equivalent with axial length, corneal radius of curvature, axial length/corneal radius of curvature ratio, and anterior chamber depth were −0.40, 0.14, −0.63, and −0.18, respectively, after controlling the effects of age, sex, and nuclear cataract. The axial length (24.84 vs. 21.21 mm), the anterior chamber depth (2.74 vs. 2.34 mm), the ratio of the axial length to the corneal radius of curvature (3.35 vs. 2.71), and the anterior chamber volume (138.59 and 105.54 mm3) were the highest and lowest in myopic and hyperopic individuals, respectively (all P < .001). In the first model, axial length and nuclear cataract were significantly inversely related to the spherical equivalent. However, corneal radius of curvature, anterior chamber depth, central corneal thickness, and corneal diameter had a significant direct relationship with the spherical equivalent. In the second model, the axial length/corneal radius of curvature ratio and cataract showed an inverse relationship with the spherical equivalent, whereas anterior chamber depth and corneal diameter had a direct relationship with the spherical equivalent.
CONCLUSIONS
Among the biometric components, the axial length/corneal radius of curvature ratio has the strongest relationship with refractive errors. The anterior chamber depth is lower in myopes compared with hyperopes after controlling the effect of axial length.
Publisher
Ovid Technologies (Wolters Kluwer Health)
Cited by
1 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献