Case Report: Role of Anterior Segment Optical Coherence Tomography for Managing Failed Endothelial Keratoplasty Graft

Author:

Roig-Revert María José,Arias-García Elena1,Ortega-Pérez Carolina1,Peris-Martínez Cristina

Affiliation:

1. FISABIO Ophthalmology Mediterranean Foundation, Valencia, Spain

Abstract

SIGNIFICANCE Some patients show poor visual outcomes after Descemet stripping automated endothelial keratoplasty. In such cases, secondary Descemet membrane endothelial keratoplasty can be performed to achieve complete visual recovery. Anterior segment optical coherence tomography (AS-OCT) is a valuable tool for the follow-up of posterior lamellar keratoplasty outcomes and complications. PURPOSE This study aimed to report the clinical outcome of secondary Descemet membrane endothelial keratoplasty for managing poor visual results in a patient with graft failure after a previous Descemet stripping automated endothelial keratoplasty, highlighting the importance of AS-OCT in the follow-up of endothelial keratoplasty. CASE REPORT A 38-year-old woman with high myopia underwent Descemet stripping automated endothelial keratoplasty for bullous keratopathy after explantation of an angle-supported phakic intraocular lens. Two years after keratoplasty, the patient experienced poor visual acuity (counting fingers), and significant corneal edema was observed on clinical examination hindering visualization of the anterior chamber structures. Anterior segment optical coherence tomography showed a failed and thickened graft adhering well to the recipient cornea in an anterior chamber without other comorbidities. Therefore, the graft was removed and replaced with a Descemet membrane endothelial keratoplasty graft without any complications. One year later, the clinical outcome was evaluated by comparing the pre-operative and post-operative best-corrected visual acuity, biomicroscopy findings, endothelial cell density, and corneal central thickness. CONCLUSIONS Anterior segment optical coherence tomography is an important tool when deciding on the surgical technique to be applied and for the post-surgical monitoring of endothelial corneal grafts. This case demonstrates the successful management of Descemet stripping automated endothelial keratoplasty graft failure with Descemet membrane endothelial keratoplasty graft, highlighting the importance of AS-OCT in detecting complications such as graft dislocation and primary graft failure. In addition, corneal thickness measured using AS-OCT serves as a critical predictor of graft failure, as observed in this case.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Optometry,Ophthalmology

Reference16 articles.

1. Descemet-stripping Automated Endothelial Keratoplasty;Cornea,2006

2. Descemet's Stripping with Endothelial Keratoplasty: Comparative Outcomes with Microkeratome-dissected and Manually Dissected Donor Tissue;Ophthalmology,2006

3. Descemet Membrane Endothelial Keratoplasty (DMEK);Cornea,2006

4. Descemet Stripping Automated Endothelial Keratoplasty versus Descemet Membrane Endothelial Keratoplasty: A Meta-analysis;Int Ophthalmol,2018

5. Descemet Membrane Endothelial Keratoplasty for Graft Failure after Descemet Stripping Endothelial Keratoplasty: Clinical Results and Histopathologic Findings;JAMA Ophthalmol,2015