Case Report: When Two Is Worse Than One—Stereo Imbalance in a Case of Wavefront-guided Scleral Lenses

Author:

Nguyen Lan Chi,Lew Wei Hau1,Kauffman Matthew J.1,Marsack Jason D.1,Applegate Raymond A.1,Coates Daniel R.1

Affiliation:

1. College of Optometry, University of Houston, Houston, Texas

Abstract

SIGNIFICANCE Wavefront-guided scleral lenses (WGSLs) reduce visually debilitating residual higher-order aberrations. Although reduced higher-order aberrations lead to improvement in monocular high-contrast visual acuity (VA), the success of the lenses in everyday life depends on additional factors such as retinal contrast, binocular balance, and stereoacuity. PURPOSE This report describes a case where WGSLs provided improved monocular vision compared with scleral lenses (SLs) but reduced binocularity and stereoacuity. CASE REPORT A 48-year-old woman with moderate keratoconus right eye (OD) and severe left eye (OS) was fitted with SLs and WGSLs. Visual acuity with best SLs was 20/20−2 OD and 20/25−2 OS. Residual higher-order root-mean-square (HORMS) wavefront error (6 mm pupil) was 0.56 μm OD and 1.38 μm OS. Visual acuity with WGSLs was 20/16−2 OD and 20/25+2 OS, and residual HORMS was 0.41 μm OD and 0.98 μm OS. Monocularly, WGSLs were reported to provide better VA. However, binocularly, the patient reported an “imbalanced feeling” and preferred the SLs over WGSLs. Binocular VA at distance was 20/25 with SLs and 20/25−2 with WGSL. To investigate, the Worth Four-Dot test was performed, and the outcomes reported fusion with SLs but suppression OS at distance with WGSLs. Stereoacuity was 160 arc seconds at near and 120 arc seconds at distance with SLs and 400 arc seconds at near and >1200 arc seconds at distance with WGSLs. Dichoptic contrast balancing showed a balance point of 0.48 with SLs and 0.17 with WGSLs, indicating a strong preference toward OD. Simulation of the patient's retinal image revealed a greater difference in image contrast between the two eyes with WGSLs. CONCLUSIONS Wavefront-guided scleral lenses reduced HORMS and improved VA compared with SLs. However, in this case, it inadvertently caused binocular imbalance. As WGSLs become more widely available, future work should include methods to optimize binocular balance to maximize overall patient satisfaction.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Optometry,Ophthalmology

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3