A Retrospective Study of Success, Failure, and Time Needed to Perform Awake Intubation

Author:

Joseph Thomas T.1,Gal Jonathan S.1,DeMaria Samuel1,Lin Hung-Mo1,Levine Adam I.1,Hyman Jaime B.1

Affiliation:

1. From the Departments of Anesthesiology (T.T.J., J.S.G., S.D., H.-M.L., A.I.L., J.B.H.), Population Health Science and Policy (H.-M.L.), Otolaryngology (A.I.L.), and Structural and Chemical Biology (A.I.L.), Icahn School of Medicine, Mount Sinai Hospital, New York, New York.

Abstract

Abstract Background Awake intubation is the standard of care for management of the anticipated difficult airway. The performance of awake intubation may be perceived as complex and time-consuming, potentially leading clinicians to avoid this technique of airway management. This retrospective review of awake intubations at a large academic medical center was performed to determine the average time taken to perform awake intubation, its effects on hemodynamics, and the incidence and characteristics of complications and failure. Methods Anesthetic records from 2007 to 2014 were queried for the performance of an awake intubation. Of the 1,085 awake intubations included for analysis, 1,055 involved the use of a flexible bronchoscope. Each awake intubation case was propensity matched with two controls (1:2 ratio), with similar comorbidities and intubations performed after the induction of anesthesia (n = 2,170). The time from entry into the operating room until intubation was compared between groups. The anesthetic records of all patients undergoing awake intubation were also reviewed for failure and complications. Results The median time to intubation for patients intubated post induction was 16.0 min (interquartile range: 13 to 22) from entrance into the operating room. The median time to intubation for awake patients was 24.0 min (interquartile range: 19 to 31). The complication rate was 1.6% (17 of 1,085 cases). The most frequent complications observed were mucous plug, endotracheal tube cuff leak, and inadvertent extubation. The failure rate for attempted awake intubation was 1% (n = 10). Conclusions Awake intubations have a high rate of success and low rate of serious complications and failure. Awake intubations can be performed safely and rapidly.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Anesthesiology and Pain Medicine

Cited by 66 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3