Lysis Onset Time as Diagnostic Rotational Thromboelastometry Parameter for Fast Detection of Hyperfibrinolysis

Author:

Dekker Simone Esther1,Viersen Victor Alexander1,Duvekot Anne1,de Jong Merijn1,van den Brom Charissa Esmé1,van de Ven Peter M.1,Schober Patrick1,Boer Christa1

Affiliation:

1. From the Department of Anesthesiology, Institute for Cardiovascular Research, VU University Medical Center, Amsterdam, The Netherlands (S.E.D., V.A.V., A.D., M.d.J., C.E.v.d.B., P.S., C.B.); and Department of Epidemiology and Biostatistics, VU University Medical Center, Amsterdam, The Netherlands (P.M.v.d.V.).

Abstract

Abstract Background: Rotational thromboelastometry is increasingly used to detect hyperfibrinolysis, which is a predictor of unfavorable outcome in patients with coagulation disturbances. In an in vitro study, the authors investigated which thromboelastometric hemostatic parameters could be valuable for fast diagnosis of the severity of hyperfibrinolysis and confirmed their findings in a patient population with hyperfibrinolysis. Methods: Thromboelastometry was performed after adding increasing concentrations of tissue plasminogen activator (0 to 400 ng/ml) to citrated blood samples of 15 healthy volunteers. Lysis parameters included the clotting time, maximum clot firmness, maximum lysis, and lysis onset time (LOT). The relation of tissue plasminogen activator with the LOT was further investigated in a patient population with out-of-hospital cardiac arrest and hyperfibrinolysis. Results: The LOT showed a dose-dependent association with increasing tissue plasminogen activator concentrations. Late, intermediate, or fulminant hyperfibrinolysis was associated with an average LOT (mean ± SD) of 42.7 ± 13.8, 23.2 ± 8.2, and 17.5 ± 4.6 min in the in vitro study and estimated 42.2 ± 8.3, 29.1 ± 1.2, and 14.6 ± 7.7 min in patients, respectively. The authors found a moderately negative correlation between patient plasma tissue plasminogen activator levels and the LOT (r = −0.67; P = 0.01). Conclusion: This study shows that the LOT may be used for fast detection of severe hyperfibrinolysis, with a better resolution than the maximum lysis, and should be further evaluated for optimization of therapeutic strategies in patients with severe clot breakdown.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Anesthesiology and Pain Medicine

Reference21 articles.

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3