Diagnostic Accuracy of Respiratory Distress Observation Scales as Surrogates of Dyspnea Self-report in Intensive Care Unit Patients

Author:

Persichini Romain1,Gay Frédérick1,Schmidt Matthieu1,Mayaux Julien1,Demoule Alexandre1,Morélot-Panzini Capucine1,Similowski Thomas1

Affiliation:

1. From the AP-HP, Groupe Hospitalier Pitié-Salpêtrière-Charles Foix, Service de Pneumologie et Réanimation Médicale (Département “R3S”), Paris, France (R.P., M.S., J.M., A.D., C.M.-P., T.S.); AP-HP, Groupe Hospitalier Pitié-Salpêtrière-Charles Foix, Pôle Biologie Médicale et Pathologie, Service de Parasitologie et Mycologie, Paris, France (F.G.); Sorbonne Universités, UPMC Univ Paris 06, UMR_S 1158

Abstract

Abstract Background: Dyspnea, like pain, can cause major suffering in intensive care unit (ICU) patients. Its evaluation relies on self-report; hence, the risk of being overlooked when verbal communication is impaired. Observation scales incorporating respiratory and behavioral signs (respiratory distress observation scales [RDOS]) can provide surrogates of dyspnea self-report in similar clinical contexts (palliative care). Methods: The authors prospectively studied (single center, 16-bed ICU, large university hospital) 220 communicating ICU patients (derivation cohort, 120 patients; separate validation cohort, 100 patients). Dyspnea was assessed by dyspnea visual analog scale (D-VAS) and RDOS calculated from its eight components (heart rate, respiratory rate, nonpurposeful movements, neck muscle use during inspiration, abdominal paradox, end-expiratory grunting, nasal flaring, and facial expression of fear). An iterative principal component analysis and partial least square regression process aimed at identifying an optimized D-VAS correlate (intensive care RDOS [IC-RDOS]). Results: In the derivation cohort, RDOS significantly correlated with D-VAS (r = 0.43; 95% CI, 0.29 to 0.58). A five-item IC-RDOS (heart rate, neck muscle use during inspiration, abdominal paradox, facial expression of fear, and supplemental oxygen) significantly better correlated with D-VAS (r = 0.61; 95% CI, 0.50 to 0.72). The median area under the receiver operating curve of IC-RDOS to predict D-VAS was 0.83 (interquartile range, 0.81 to 0.84). An IC-RDOS of 2.4 predicted D-VAS of 4 or greater with equal sensitivity and specificity (72%); an IC-RDOS of 6.3 predicted D-VAS of 4 or greater with 100% specificity. Similar results were found in the validation cohort. Conclusions: Combinations of observable signs correlate with dyspnea in communicating ICU patients. Future studies in noncommunicating patients will be needed to determine the responsiveness to therapeutic interventions and clinical usefulness.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Anesthesiology and Pain Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3