Physiologic Evaluation of Ventilation Perfusion Mismatch and Respiratory Mechanics at Different Positive End-expiratory Pressure in Patients Undergoing Protective One-lung Ventilation

Author:

Spadaro Savino1,Grasso Salvatore1,Karbing Dan Stieper1,Fogagnolo Alberto1,Contoli Marco1,Bollini Giacomo1,Ragazzi Riccardo1,Cinnella Gilda1,Verri Marco1,Cavallesco Narciso Giorgio1,Rees Stephen Edward1,Volta Carlo Alberto1

Affiliation:

1. From the Department of Morphology, Surgery and Experimental Medicine, Intensive Care Unit, Sant’Anna Hospital, Ferrara, Italy (S.S., A.F., G.B., R.R., M.V., N.G.C., C.A.V.); Department of Emergency and Organ Transplant, Aldo Moro University of Bari, Bari, Italy (S.G.); Respiratory and Critical Care Group, Department of Health Science and Technology, Aalborg University, Aalborg, Denmark (D.S.K., S

Abstract

Abstract Background Arterial oxygenation is often impaired during one-lung ventilation, due to both pulmonary shunt and atelectasis. The use of low tidal volume (VT) (5 ml/kg predicted body weight) in the context of a lung-protective approach exacerbates atelectasis. This study sought to determine the combined physiologic effects of positive end-expiratory pressure and low VT during one-lung ventilation. Methods Data from 41 patients studied during general anesthesia for thoracic surgery were collected and analyzed. Shunt fraction, high V/Q and respiratory mechanics were measured at positive end-expiratory pressure 0 cm H2O during bilateral lung ventilation and one-lung ventilation and, subsequently, during one-lung ventilation at 5 or 10 cm H2O of positive end-expiratory pressure. Shunt fraction and high V/Q were measured using variation of inspired oxygen fraction and measurement of respiratory gas concentration and arterial blood gas. The level of positive end-expiratory pressure was applied in random order and maintained for 15 min before measurements. Results During one-lung ventilation, increasing positive end-expiratory pressure from 0 cm H2O to 5 cm H2O and 10 cm H2O resulted in a shunt fraction decrease of 5% (0 to 11) and 11% (5 to 16), respectively (P < 0.001). The Pao2/Fio2 ratio increased significantly only at a positive end-expiratory pressure of 10 cm H2O (P < 0.001). Driving pressure decreased from 16 ± 3 cm H2O at a positive end-expiratory pressure of 0 cm H2O to 12 ± 3 cm H2O at a positive end-expiratory pressure of 10 cm H2O (P < 0.001). The high V/Q ratio did not change. Conclusions During low VT one-lung ventilation, high positive end-expiratory pressure levels improve pulmonary function without increasing high V/Q and reduce driving pressure.

Publisher

Ovid Technologies (Wolters Kluwer Health)

Subject

Anesthesiology and Pain Medicine

Reference53 articles.

1. One-lung ventilation and hypoxic pulmonary vasoconstriction: Implications for anesthetic management.;Anesth Analg,1985

2. The lung during and after thoracic anaesthesia.;Curr Opin Anaesthesiol,2005

3. Effects of PEEP on oxygenation and respiratory mechanics during one-lung ventilation.;Br J Anaesth,2005

4. Pulmonary atelectasis: A pathogenic perioperative entity.;Anesthesiology,2005

5. Alveolar recruitment strategy increases arterial oxygenation during one-lung ventilation.;Ann Thorac Surg,2002

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3